| 查看: 235 | 回复: 2 | |||
| 当前主题已经存档。 | |||
| 当前只显示满足指定条件的回帖,点击这里查看本话题的所有回帖 | |||
WHQ197木虫 (正式写手)
|
[交流]
翻译一段话
|
||
| 实验装置如图1所示:干燥电极被分别放置于三个长方体金属箱体内,一箱体内上电极为线电极(将细铜线固定于金属框上,铜线之间的间隔可调),下电极为金属板(上下电极间隔可调),一箱体内上电极为针电极(将缝衣针穿于铜线上,针与针之间的间隔可调),下电极为金属板(上下电极间隔可调),另一箱体内上下电极为金属板电极,(间隔可调),同时在每个箱体内装有温度传感器,能够监控箱体内的温度,箱体上部设有通气孔。所用高压电源为一电压连续可调的正高压电源。 |
» 猜你喜欢
有时候真觉得大城市人没有县城人甚至个体户幸福
已经有9人回复
CSC & MSCA 博洛尼亚大学能源材料课题组博士/博士后招生|MSCA经费充足、排名优
已经有6人回复
天津大学招2026.09的博士生,欢迎大家推荐交流(博导是本人)
已经有4人回复
同年申请2项不同项目,第1个项目里不写第2个项目的信息,可以吗
已经有3人回复
退学或坚持读
已经有28人回复
面上项目申报
已经有3人回复
酰胺脱乙酰基
已经有9人回复
博士延得我,科研能力直往上蹿
已经有7人回复
面上基金申报没有其他的参与者成吗
已经有5人回复
遇见不省心的家人很难过
已经有22人回复
wshbinzhang
铁杆木虫 (知名作家)
- 翻译EPI: 3
- 应助: 0 (幼儿园)
- 金币: 7807.3
- 散金: 200
- 帖子: 5830
- 在线: 153.7小时
- 虫号: 478725
- 注册: 2007-12-14
- 专业: 结构陶瓷
★ ★ ★ ★
WHQ197(金币+4,VIP+0):thank you 2-6 20:10
WHQ197(金币+4,VIP+0):thank you 2-6 20:10
|
The experimental equipment was shown in Figure 1. The dry electrodes were placed in three rectangular metal tanks, and the distance between electrodes could be adjustive. For the first tank, the upper electrode was a wire electrode (tiny copper wires were fixed at the metal frame with the adjustable distance), and the under electrode was a metal plate. For the second, the upper electrode was a needle electrode (needles were placed between copper wires with the adjustable distance), the under electrode was a metal plates. For the third, both the upper and under electrodes were metal plates. A ventilating hole was drilled on the top of each tank, and a temperature sensor was equipped to monitor and control the temperatures. The used power was a continuously adjustable high voltage power. |
3楼2009-02-05 17:13:25
DifficultFlying
铜虫 (小有名气)
- 应助: 0 (幼儿园)
- 金币: 35.4
- 帖子: 209
- 在线: 20.2小时
- 虫号: 462342
- 注册: 2007-11-19
- 性别: GG
- 专业: 光学
抛砖引玉!希望对你有所帮助,但是你的文字表达能力好像比我还差。
★ ★ ★ ★ ★ ★
WHQ197(金币+6,VIP+0):thank you 2-6 20:09
WHQ197(金币+6,VIP+0):thank you 2-6 20:09
| Experimental apparatus was shown in Figure 1: three dry electrodes were placed in three rectangular metal box respectively. In the first box, the top electrodes was wire electrode (some small copper wires were fixed at a metal frame, and the spacing between the small copper wires was adjustable), the bottom electrode was metal plates, and spacing between the two electrodes can be adjustable. In the second box, the top electrodes was needle electrode (some sewing needles were linked with copper, and spacing between the needles can be adjustable), the bottom electrode was metal plates, and spacing between the two electrodes can be adjustable. In the third box, the top and bottom electrodes were both metal plate, with the spacing between those two electrodes adjustable. In each box, a temperature sensor was equipped to monitor and control the temperature, and there has one ventilating hole on the above of the box. A continuously adjustable high voltage power supply was used as the high voltage power supply |

2楼2009-02-04 22:06:07













回复此楼