vaspÓÅ»¯½á¹¹±¨´íZBRENT: fatal error in bracketingÒÑÓÐ1È˲ÎÓë
|
||||
|
¸÷λ´óÉñ£¬¸Õ¸ÕʹÓÃvasp²»¾Ã£¬ÓÅ»¯½á¹¹×ÜÊÇÓöµ½Ò»Ð©ÎÊÌ⣬¸ù¾ÝÍøÉϲéѯµÄ°ì·¨Ëƺõ¶¼Ã»ÓÐʲôЧ¹û£¬ËùÒÔÇëÓж®µÄ´óÉñÄܹ»¸øÓèÒ»µãÖ¸µ¼£¬¸Ð¼¤²»¾¡¡£ ZBRENT: fatal error in bracketing please rerun with smaller EDIFF, or copy CONTCAR to POSCAR and continue ÎÒÊDzÉÓÃISIF=2,ISIF=7,ISIF=2,ISIF=7µÄ·½Ê½£¬À´ÓÅ»¯½á¹¹µÄ£¬¶ÔÓÚunit cellÀ´Ëµ£¬ÓÅ»¯µÄºÜºÃ¡£È»ºó³¬°ûºó£¬¸Ä±äï®Àë×ÓµÄÊýÄ¿£¬ÓÅ»¯Ò»Ð©½á¹¹¡£ÔÙÓÅ»¯ÕâЩ½á¹¹Ê±£¬ÏȲÉÓÃISIF=2ÓÅ»¯³É¹¦£¬È»ºóISIF=7ÓÅ»¯¾§¸ñ³£Êý£¬µ«ÕâÒ»²½Ò»Ö±ÎÞ·¨³É¹¦£¬×ÜÊdzöÏÖÉÏÃæµÄ´íÎó¡£ ÊÔ¹ýµÄ·½·¨£º 1. ¸ù¾ÝÌáʾCONTCAR±äPOSCAR¼ÌÐøÓÅ»¯£¬»òÕßʹÓøüСµÄEDIFF£¬¶¼ÈÔȻһÑùµÄ±¨´í¡£ 2. IBRION¸ÄΪ1¼ÆË㣬ÏÖÔÚÒѾËãÁË120¸öÀë×Ó²½ÁË»¹Î´ÊÕÁ²£¬ÓÅ»¯½á¹¹ºóÃæÊµÊ±¸üС£ 3. IBRION=1£¬²¢ÇÒADDGRID=TRUE½øÐÐÓÅ»¯£¬ÓÅ»¯½á¹¹ºóÃæ¸üС££¨ADDGRID¼òµ¥²âÊÔÁËһϣ¬Ëƺõ¶ÔÄÜÁ¿Ã»ÓÐʲôӰÏ죩 4. IBRION²»±ä£¬ÈÔÈ»=2£¬¼ÓÈëADDGRID=TRUE½øÐÐÓÅ»¯£¬½á¹ûºóÃæ¸üС£ ÏÖÔÚͨ¹ý²é×ÊÁÏÕÒµ½µÄ¾ÍÕâЩ·½·¨¡£ ÇëÎÊ´ó¼Ò£º 1. Õâ¸ö±¨´íµÄÔÒòÊÇʲô£¿ 2. ÈçºÎÓÐЧ½â¾öÕâ¸ö±¨´íÄØ£¿ 3. ¿´µ½ÓÐÈË˵Õâ¸ö¸úvaspµÄ±àÒëÓйأ¿ÇëÎÊÕâ¸ö¸ÃÈçºÎÀí½â£¬¾ßÌåָʲôÏà¹ØÄØ£¿ £¨±¾È˲»Ì«ÏàÐÅÕâÖÖÔÒò£© 4. ADDGRIDµÄ¾ßÌ庬ÒåÊÇʲô£¬ÓÐʲôӰÏ죿vasp¼ÆËãºÃÏñºÜÉÙ¿´µ½Õâ¸ö²ÎÊý¡£ ±¾È˵ÄÊäÈëÎļþ¾ùÒÑÉÏ´«¡£ Çë´ó¼ÒÄܹ»»¨µãʱ¼äÒ»ÆðÌÖÂÛһϣ¬Thanks a lot ! |
» ±¾Ìû¸½¼þ×ÊÔ´Áбí
-
»¶Ó¼à¶½ºÍ·´À¡£ºÐ¡Ä¾³æ½öÌṩ½»Á÷ƽ̨£¬²»¶Ô¸ÃÄÚÈݸºÔð¡£
±¾ÄÚÈÝÓÉÓû§×ÔÖ÷·¢²¼£¬Èç¹ûÆäÄÚÈÝÉæ¼°µ½ÖªÊ¶²úȨÎÊÌ⣬ÆäÔðÈÎÔÚÓÚÓû§±¾ÈË£¬Èç¶Ô°æÈ¨ÓÐÒìÒ飬ÇëÁªÏµÓÊÏ䣺xiaomuchong@tal.com - ¸½¼þ 1 : POSCAR
- ¸½¼þ 2 : POTCAR
2017-07-17 10:07:07, 12.01 K
2017-07-17 10:28:46, 613.53 K
» ±¾ÌûÒÑ»ñµÃµÄºì»¨£¨×îÐÂ10¶ä£©
» ²ÂÄãϲ»¶
ƸU VÈÈÈÛ½ºÑо¿ÈËÔ±
ÒѾÓÐ9È˻ظ´
Ö°³ÆÆÀÉóû¹ý£¬Çó°²Î¿
ÒѾÓÐ5È˻ظ´
À¬»øÆÆ¶þ±¾Ö°³ÆÆÀÉó±ê×¼
ÒѾÓÐ10È˻ظ´
Ͷ¸å·µÐÞºóÊÕµ½ÕâÑùµÄ»Ø¸´£¬»¹ÓÐÏ£ÍûÂð
ÒѾÓÐ8È˻ظ´
ÈýÎÞ²úÆ·»¹Óлú»áÂð
ÒѾÓÐ6È˻ظ´
²©Ê¿ÉêÇë¶¼ÊÇÄÚ¶¨µÄÂð£¿
ÒѾÓÐ14È˻ظ´
̸̸Á½ÌìÒ»Ò¹µÄ¡°ÑÓ°²ÐС±
ÒѾÓÐ13È˻ظ´
°±»ù·â¶ËPDMSºÍHDI·´Ó¦¿ìËٹ̻¯
ÒѾÓÐ11È˻ظ´
ÂÛÎÄͶ¸åÇóÖú
ÒѾÓÐ4È˻ظ´
Applied Surface Science Õâ¸öÆÚ¿¯¡£ÓÐÄÄλ³æÓÑͶ¹ýµÄÄܰÑwordÄ£°å·¢¸øÎҲο¼Ò»ÏÂÂï
ÒѾÓÐ3È˻ظ´
jpchou
ר¼Ò¹ËÎÊ (ÖøÃûдÊÖ)
-

ר¼Ò¾Ñé: +20 - 1STÇ¿Ìû: 5
- Ó¦Öú: 231 (´óѧÉú)
- ½ð±Ò: 2342
- É¢½ð: 4367
- ºì»¨: 103
- Ìû×Ó: 1061
- ÔÚÏß: 757.3Сʱ
- ³æºÅ: 585915
- ×¢²á: 2008-08-08
- ÐÔ±ð: GG
- רҵ: Äý¾Û̬ÎïÐÔ II £ºµç×ӽṹ
- ¹ÜϽ: µÚÒ»ÐÔÔÀí
¡¾´ð°¸¡¿Ó¦Öú»ØÌû
¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï
¸Ðл²ÎÓ룬ӦÖúÖ¸Êý +1
Àî«h«h: ½ð±Ò+15, ¡ï¡ï¡ïºÜÓаïÖú 2017-07-17 19:45:03
ÂþÌìÆ®Ñ©: ½ð±Ò+2, лл½»Á÷ 2017-07-17 20:45:33
¸Ðл²ÎÓ룬ӦÖúÖ¸Êý +1
Àî«h«h: ½ð±Ò+15, ¡ï¡ï¡ïºÜÓаïÖú 2017-07-17 19:45:03
ÂþÌìÆ®Ñ©: ½ð±Ò+2, лл½»Á÷ 2017-07-17 20:45:33
|
ß@†–î}ż –•þ³ö¬F ÎÒÏ룬ŸoÕ“ÊÇÕlÌø³ö?í½âጣ¬VASP×÷ÕßȺµÄ¹«ÐÅÁ¦ÈÔÊDZÈÝ^¸ßµÄ http://cms.mpi.univie.ac.at/vasp ... ?f=3&t=7415 ÑeÃæµÄ admin (Ò²¾ÍÊÇ VASP ¹Ù·½Õ“‰¯µÄ¹ÜÀí†T£¬Éí·Ýëm²»´_¶¨£¬µ«~ Ò»¶¨¸ú VASP ×÷ÕßȺÓÐÖ±½ÓêPßB) please have a look at the OUTCAR file, at the forces of the last ionic step before Brent's algorithm fails -- if the calculation is very well-converged already, please proceed using IBRION=1; ADDGRID=.TRUE. and a larger ENCUT ß@Ò»ücÊÇÅcÄãÌá³öµÄ½âጷ½·¨ 3 ÊÇÒ»Ö嵀 ²»ß^£¬Ç°ÌáÊÇÈç¹ûÄãµÄÓ‹ËãÒѽ› "¿ìÒª" ÊÕ”¿ÁË -- if this error appears at an early stage of the relaxation, pelase check if your input geometry was reasonable, eg by having a look at the interatomic distances (written in OUTCAR) or the forces of the first geometries. It may then help to increase the accuracy (PREC= Accurate and a higher ENCUT) and to decrease POTIM to avoid too large stepwidhts in the first relaxation step. ÈôÊÇÄãµÄÓ‹ËãëxÊÕ”¿ß€ºÜßh£¬Õˆ™z²éÄãµÄ½Y˜‹ÊÇ·ñºÏÀí ™z²é OUTCAR ƒÈµÚÒ»‚€ ionic loop µÄ FORCE£¬¿´¿´ÊÇ·ñÓÐÔ×Ó³ö¬F²»Œ¤³£´óµÄÊÜÁ¦ ͸ß^ PREC=Accurate & ENCUT ¼Ó´ó & ½µµÍ POTCAR£¬Ò²ÔS•þÓÐŽÍÖú http://cms.mpi.univie.ac.at/vasp ... p?f=3&t=869 this message says that during geometry optimisation no reasonable next step could be found with Brent's algorithm (linear bisectioning) please check the following 1) is the system converged already? (look at the forces in OUTCAR, especially if you use the total energy change as congvergence criterium for ionic optimisation) 2) if not: is each ionic step converged electronically ( this is needed to obtain reasonable forces) ß@ƪµÄ»Ø‘ª„‚ÉÏÆªÊÇ´óͬС®?£¬´ËÍ⣬admin ÔÚÏÂÃæÓÖÔÙÌáµ½Õf sometimes, if the calculation is already highly converged, vasp cannot interpolate the next step to within the numerical accuracy because it simply would be so small. (this behaviour is machine-dependent). If you have used IBRION=2, it may help to switch to IBRION=1 and set ADDGRID=.true. in addition ´ËücÊÇÅcÄãÕfµÄ½â›Q·½·¨ 4 ÊÇÒ»Ö ´ËÍâ http://cms.mpi.univie.ac.at/vasp-forum/viewtopic.php?t=1856 ZBRENT is an algorithm search for a root of a function by Brent's method: Numerical recipies, Section 9.3 The problem in your case might be that the Conjugate Gradient algorithm (IBRION=2) is not suitable for very small corrections of the atomic positions if your system has almost reached equilibrium (please have a look at XDATCAR to check the size of the relaxation steps done before the ZBRENT warnings show up). Usually it is sufficient to converge a system up to maximum remaining forces of about 0.01eV/A (EDIFFG=-0.01). please try one of the following: 1) choose a different algorithm for ionic optimization (IBRION=1) 2) set ADDGRID=.True. in INCAR (only for vasp releases 4.4.5 and newer) Admin ᘌ¦ ZBRENT Ò²ÓÐÌá³öÕfÃ÷ ZBRENT ÊÇ”µÖµ·½·¨ƒÈµÄ Brent's method ÔÚÄãÓ‹ËãÒѽ›ºÜ½Ó½üÊÕ”¿•r£¬VASP Ëù×öµÄ displacement •þ׃µÄºÜС ¾ÍÓпÉÄÜ•þʹµÃß@‚€ Brent's method ®aÉú†–î} ‚€È˽›òž ß@†–î}´ó¶à³ö¬FÔÚ structure optimization •r ͨ³£¾ÍÊÇVASPÔÚÕÒ optimized position ®aÉúÁËÕð±U ¾ÍºÃÏñÊÇ (ÒÔÏÂÊÇÏëÏñ£¬”µ×Ö¶¼ÊÇÎÒëSÒâ½oµÄ) ij‚€Ô×Ó×î¼ÑλÖÃÊÇÔÚ 0.5 ¶ø¬FÔÚλÖÃÊÇ 0.4£¬Ã¿´ÎVASP•þÒÆ„Ó 0.2 Ô×Ӿ͕þ?Ä 0.4 Ìøµ½ 0.6 È»ááÓÖÌø»Ø 0.4 ÓÖÔÙÌø»Ø 0.6 ËùÒÔÓ‹ËãÒ»Ö±Ÿo·¨Õý³£Í£Ö¹ ½Y˜‹ÅcÄÜÁ¿Ò²•þÊÇÔÚijƒÉ‚€ÖµégÒ»Ö±Õð±U ß@Ò²ÊÇžéʲüN¸Ä׃ IBRION ÊÇÓЙC•þ¿ÉÒÔ½â›Qß@†–î} |
3Â¥2017-07-17 18:02:42
Àî«h«h
ͳæ (ÕýʽдÊÖ)
- Ó¦Öú: 1 (Ó×¶ùÔ°)
- ½ð±Ò: 744.5
- ºì»¨: 5
- ɳ·¢: 1
- Ìû×Ó: 347
- ÔÚÏß: 63.2Сʱ
- ³æºÅ: 4230820
- ×¢²á: 2015-11-19
- ÐÔ±ð: GG
- רҵ: ÀíÂۺͼÆË㻯ѧ
|
½ð±Ò²»¶à£¬´ó¼Ò¼ûÁ£¬¸½ÉÏINCARºÍKPOINTS£¬ÉÏ´«³öÎÊÌâÁË¡£¡£¡£¡£ INCAR: SYSTEM = LiFePO4_1 ######Start Parameter for This Run ISTART = 0 ICHARG = 2 INIWAV = 1 ######Electronic Relaxation ENCUT = 520 NELM = 60 EDIFF = 1E-5 GGA = PE ISMEAR = 0 SIGMA = 0.05 PREC = Accurate ISPIN = 2 #LORBIT = 10 ######Ion Relaxation IBRION = 2 ISIF = 2 NSW = 200 EDIFFG = -0.01 POTIM = 0.5 ALGO = Fast LREAL = A NPAR=4 ######LDA+U LMAXMIX = 4 LDAU = .TRUE. LDAUTYPE = 2 LDAUL = 2 -1 -1 -1 LDAUU = 5.3 0 0 0 LDAUJ = 1.0 0 0 0 #for out LCHARG = .FALSE. LWAVE = .FALSE. LVTOT = .FALSE. LELF = .FALSE. KPOINTS: k-points 0 Monkhorst Pack 4 3 4 0 0 0 »¶Ó´ó¼Ò·¢ÑÔ |
2Â¥2017-07-17 10:39:24
Àî«h«h
ͳæ (ÕýʽдÊÖ)
- Ó¦Öú: 1 (Ó×¶ùÔ°)
- ½ð±Ò: 744.5
- ºì»¨: 5
- ɳ·¢: 1
- Ìû×Ó: 347
- ÔÚÏß: 63.2Сʱ
- ³æºÅ: 4230820
- ×¢²á: 2015-11-19
- ÐÔ±ð: GG
- רҵ: ÀíÂۺͼÆË㻯ѧ
4Â¥2017-07-17 19:50:31
Àî«h«h
ͳæ (ÕýʽдÊÖ)
- Ó¦Öú: 1 (Ó×¶ùÔ°)
- ½ð±Ò: 744.5
- ºì»¨: 5
- ɳ·¢: 1
- Ìû×Ó: 347
- ÔÚÏß: 63.2Сʱ
- ³æºÅ: 4230820
- ×¢²á: 2015-11-19
- ÐÔ±ð: GG
- רҵ: ÀíÂۺͼÆË㻯ѧ
|
½ñÌì´óÖ²âÊÔÁËһϣ¬½öÒÔ±¾Ìåϵ¸ú´ó¼Ò˵һϲâÊԵĽá¹û£º 1. ½ö¸Ä±äÁËIBRION=1£¬µ«¼ÆËã´ïµ½ÁËNSWµÄÉÏÏÞ£¨200£©ÈÔȻδÊÕÁ². 2. Ö±½Ó¼ÓÉÏADDGRID=TRUE£¬ÈÔȻһÑùµÄ±¨´í£¬¼ÆËãʧ°Ü 3. ¸Ä±äIBRION=1 + ADDGRID=TRUE , Õâ¸ö·½·¨Ëƺõ±È½ÏÓÐЧ£¬¼ÆËãÕý³££¬¼¸Ê®²½¾ÍÊÕÁ²ÁË ¶ÔÓÚ²»Í¬µÄÌåϵ¿ÉÄÜÓв»Í¬µÄ½á¹û£¬½÷ÒԴ˲ο¼¡£ ´ó¼ÒÓÐʲô½¨Òé»òÕß¾Ñ飬»¶ÓÁôÑÔ£¡ |