[求助] check CIF出现A问题 已有1人参与

Alert level A
SYMM001_ALERT_1_A  _symmetry_cell_setting is missing
            The cell setting should be one of the following
            *  triclinic
            *  monoclinic
            *  orthorhombic
            *  tetragonal
            *  rhombohedral
            *  trigonal
            *  hexagonal
            *  cubic
            The following tests will not be performed.
            SYMMS_01,SYMMS_02
EXPT005_ALERT_1_A  _exptl_crystal_description is missing
            Crystal habit description.
            The following tests will not be performed.
            CRYSR_01
DIFF003_ALERT_1_A  _diffrn_measurement_device_type is missing
            Diffractometer make and type. Replaces _diffrn_measurement_type.
PLAT043_ALERT_1_A Calculated and Reported Mol. Weight Differ by ..     289.57 Check
PLAT051_ALERT_1_A Mu(calc) and Mu(CIF) Ratio Differs from 1.0 by .     299.79 %     
PLAT122_ALERT_1_A No _symmetry_space_group_name_H-M Given ........     Please Do !
PLAT183_ALERT_1_A Missing _cell_measurement_reflns_used value ....     Please Do !
PLAT184_ALERT_1_A Missing _cell_measurement_theta_min value ......     Please Do !
PLAT185_ALERT_1_A Missing _cell_measurement_theta_max value ......     Please Do !
回复此楼
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖

张在永

木虫 (正式写手)

【答案】应助回帖

感谢参与,应助指数 +1
都是一些信息缺失,把z值改成正确的就能解决了

发自小木虫IOS客户端
相信自己
2楼2016-11-13 13:01:19
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖

英木花木

新虫 (初入文坛)

引用回帖:
2楼: Originally posted by 张在永 at 2016-11-13 13:01:19
都是一些信息缺失,把z值改成正确的就能解决了

那这个都是根据check 中测出来数据改成前面那个么。

发自小木虫IOS客户端
3楼2016-11-13 13:25:48
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖