| ²é¿´: 672 | »Ø¸´: 2 | ||
˧µÃÎÞ·¨ºôÎüгæ (СÓÐÃûÆø)
|
[ÇóÖú]
¿ÒÇë°ïæ½âÎöÒ»¾§Ìå лл ÒÑÓÐ1È˲ÎÓë
|
| ¾§ÌåÐÅÏ¢ÔÚѹËõ°üÀï |
» ±¾Ìû¸½¼þ×ÊÔ´Áбí
-
»¶Ó¼à¶½ºÍ·´À¡£ºÐ¡Ä¾³æ½öÌṩ½»Á÷ƽ̨£¬²»¶Ô¸ÃÄÚÈݸºÔð¡£
±¾ÄÚÈÝÓÉÓû§×ÔÖ÷·¢²¼£¬Èç¹ûÆäÄÚÈÝÉæ¼°µ½ÖªÊ¶²úȨÎÊÌ⣬ÆäÔðÈÎÔÚÓÚÓû§±¾ÈË£¬Èç¶Ô°æÈ¨ÓÐÒìÒ飬ÇëÁªÏµÓÊÏ䣺xiaomuchong@tal.com - ¸½¼þ 1 : LHM.zip
2016-03-22 14:39:19, 9.92 M
» ²ÂÄãϲ»¶
ÔÚMOFÖУ¬ÓÐûÓÐôÈ»ù²Î¼ÓÅäλµÄÇé¿ö
ÒѾÓÐ2È˻ظ´
ÕÐ2026ÄêÈëѧÉϺ£½»Í¨´óѧ²©Ê¿Éú£¬¼±£¡£¡£¡
ÒѾÓÐ1È˻ظ´
ÎÞ»ú»¯Ñ§ÂÛÎÄÈóÉ«/·ÒëÔõôÊÕ·Ñ?
ÒѾÓÐ151È˻ظ´
ÀíÂÛ¼ÆËãºÏ×÷
ÒѾÓÐ0È˻ظ´
Çó¸ßУºÏ×÷
ÒѾÓÐ1È˻ظ´
27¼¶ÎÞ»ú»¯Ñ§É격×Ô¼ö
ÒѾÓÐ2È˻ظ´
ChemdrawÃâ·ÑÈí¼þ
ÒѾÓÐ0È˻ظ´
µ¥¾§½á¹¹½âÎö£¬¸÷ÀàÒÉÄѾ§ÌåÊý¾Ý´¦ÀíºÍ´ðÒÉ
ÒѾÓÐ38È˻ظ´
Õâ¸öË®Ïà·´Ó¦ÓÐûÓд߻¯¼Á´Ù½ø·¢Éú
ÒѾÓÐ4È˻ظ´
Mn Me3TACN
ÒѾÓÐ5È˻ظ´
ÎÄÑÔÎÄ
Ìú¸Ëľ³æ (ÖøÃûдÊÖ)
- Ó¦Öú: 134 (¸ßÖÐÉú)
- ½ð±Ò: 3748.1
- É¢½ð: 295
- ºì»¨: 40
- Ìû×Ó: 1429
- ÔÚÏß: 572.2Сʱ
- ³æºÅ: 652093
- ×¢²á: 2008-11-11
- רҵ: Åäλ»¯Ñ§
¡¾´ð°¸¡¿Ó¦Öú»ØÌû
¸Ðл²ÎÓ룬ӦÖúÖ¸Êý +1
| Êý¾Ý¼û¸½¼þ£¬Î¨Ò»µÄÎÊÌâÊÇÅäÌåÓÐЩÎÞÐò£¬ÎÒûÓÐʱ¼ä´¦Àí£¬ÄãÏÈÓÃ×Å¿´£¬ÎÒÓÐʱ¼äÔÚ´¦Àí°É¡£ |
» ±¾Ìû¸½¼þ×ÊÔ´Áбí
-
»¶Ó¼à¶½ºÍ·´À¡£ºÐ¡Ä¾³æ½öÌṩ½»Á÷ƽ̨£¬²»¶Ô¸ÃÄÚÈݸºÔð¡£
±¾ÄÚÈÝÓÉÓû§×ÔÖ÷·¢²¼£¬Èç¹ûÆäÄÚÈÝÉæ¼°µ½ÖªÊ¶²úȨÎÊÌ⣬ÆäÔðÈÎÔÚÓÚÓû§±¾ÈË£¬Èç¶Ô°æÈ¨ÓÐÒìÒ飬ÇëÁªÏµÓÊÏ䣺xiaomuchong@tal.com - ¸½¼þ 1 : LHM.rar
2016-03-23 09:24:31, 1.03 M
2Â¥2016-03-23 09:24:34
ÎÄÑÔÎÄ
Ìú¸Ëľ³æ (ÖøÃûдÊÖ)
- Ó¦Öú: 134 (¸ßÖÐÉú)
- ½ð±Ò: 3748.1
- É¢½ð: 295
- ºì»¨: 40
- Ìû×Ó: 1429
- ÔÚÏß: 572.2Сʱ
- ³æºÅ: 652093
- ×¢²á: 2008-11-11
- רҵ: Åäλ»¯Ñ§
¡¾´ð°¸¡¿Ó¦Öú»ØÌû
¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ...
˧µÃÎÞ·¨ºôÎü: ½ð±Ò+80, ¡ï¡ï¡ï¡ï¡ï×î¼Ñ´ð°¸, ллÄú Êý¾ÝÌ«ºÃÁË 2016-03-23 16:47:00
˧µÃÎÞ·¨ºôÎü: ½ð±Ò+80, ¡ï¡ï¡ï¡ï¡ï×î¼Ñ´ð°¸, ллÄú Êý¾ÝÌ«ºÃÁË 2016-03-23 16:47:00
|
ÎÞÐò¿ÉÒÔ²»Óô¦Àí£¬ÌîÒ»ÏÂcifÎļþ¾ÍûÓÐAÀà´íÎóÁË¡£ Alert level A EXPT005_ALERT_1_A _exptl_crystal_description is missing Crystal habit description. The following tests will not be performed. CRYSR_01 DIFF003_ALERT_1_A _diffrn_measurement_device_type is missing Diffractometer make and type. Replaces _diffrn_measurement_type. PLAT183_ALERT_1_A Missing _cell_measurement_reflns_used value .... Please Do ! PLAT184_ALERT_1_A Missing _cell_measurement_theta_min value ...... Please Do ! PLAT185_ALERT_1_A Missing _cell_measurement_theta_max value ...... Please Do ! Alert level C PLAT052_ALERT_1_C Info on Absorption Correction Method Not Given Please Do ! PLAT053_ALERT_1_C Minimum Crystal Dimension Missing (or Error) ... Please Check PLAT054_ALERT_1_C Medium Crystal Dimension Missing (or Error) ... Please Check PLAT055_ALERT_1_C Maximum Crystal Dimension Missing (or Error) ... Please Check PLAT220_ALERT_2_C Large Non-Solvent C Ueq(max)/Ueq(min) Range 5.2 Ratio PLAT222_ALERT_3_C Large Non-Solvent H Uiso(max)/Uiso(min) ... 5.0 Ratio PLAT230_ALERT_2_C Hirshfeld Test Diff for C31 -- C36 .. 5.5 s.u. PLAT241_ALERT_2_C High 'MainMol' Ueq as Compared to Neighbors of C37 Check PLAT242_ALERT_2_C Low 'MainMol' Ueq as Compared to Neighbors of C29 Check PLAT244_ALERT_4_C Low 'Solvent' Ueq as Compared to Neighbors of C39 Check |
3Â¥2016-03-23 09:28:48









»Ø¸´´ËÂ¥
20