[Chemical Science] Simple probe for heparin quality control
|
|
http://www.rsc.org/chemistryworl ... chondroitin-sulfate 7 August 2015Suzanne Howson http://www.rsc.org/chemistryworl ... 238218052_300tb.jpg Heparin is used to prevent blood clots © Shutterstock Scientists in China have developed a fluorescent probe to detect both heparin and its major contaminant. The sensor could make it easier to monitor the quality of heparin supplies. Heparin is widely used as an anticoagulant in cardiovascular surgery as well as in post-operative and long-term therapy. Millions of patients are treated with it each year; in 2013 sales of low molecular weight heparin reached $6.5 billion (£4.2 billion). Heparin doses must be maintained within a strict range because overdoses can have numerous side-effects, such as unusual bleeding and blood in the urine. Purity is also an important issue. It is not unheard of for the contaminant oversulfated chondroitin sulfate (OSCS) to slip into the heparin supply chain. OSCS mimics heparin in many tests but can lead to severe adverse reactions. 150 deaths between 2004 and 2008 in the US were thought to be a result of drug manufacturers deliberately cutting heparin with OSCS to save money. Activated clotting or activated partial thromboplastin time assays are currently used to calculate heparin doses, but these are time-consuming, expensive and can be unreliable. And identifying OSCS in heparin currently requires methods such as high performance liquid chromatography combined with NMR and mass spectrometry, which require expensive and sophisticated instruments and experienced operators. This prompted Hui Wei and co-workers at Nanjing University in China to design a single fluorescent probe capable of detecting and quantifying heparin and OSCS, which can be applied to both unfractioned heparin and low molecular weight heparin – the two main heparin products used clinically. The probe combines a peptide that recognises heparin as well as a fluorogen signalling component – in the presence of heparin the probe molecules aggregate and fluoresce with a detection limit as low as 3.8ng/ml. If the enzyme heparinise is then added to the test sample, the same probe can check for OSCS with a detection limit of 0.001% (w%). This is because OSCS inhibits heparinise, which would normally break the probe–heparin interactions and cause a reduction in the fluorescence. Other biological molecules do not appear to interfere with the probe. Wei says the ‘method could not only simplify the detection of heparin but also shorten its detection time, which in turn could reduce the burden on patients. And, the OSCS identification strategy may provide an alternative way to control heparin quality.’ Biosensors experts are enthusiastic about the sensor. Ben Zhong Tang from the Hong Kong University of Science and Technology particularly likes the design and envisages that ‘this smart strategy will generate a large array of light up biosensors with outstanding performance.’ And Kenneth Kam-Wing Lo from the City University of Hong Kong says ‘this interesting work will inspire the development of molecular probes and assays for biomolecules with high selectivity and sensitivity.’ Wei is currently working on these ideas as well as applying the probe to real blood samples. REFERENCES This article is open access. Download it here: Y Ding, L Shi and H Wei, Chem. Sci., 2015, DOI: 10.1039/c5sc01675d http://pubs.rsc.org/en/Content/A ... 01675d#!divAbstract |
» 猜你喜欢
寻求一种能扛住强氧化性腐蚀性的容器密封件
已经有7人回复
到新单位后,换了新的研究方向,没有团队,持续积累2区以上论文,能申请到面上吗
已经有8人回复
申请2026年博士
已经有6人回复
请问哪里可以有青B申请的本子可以借鉴一下。
已经有5人回复
天津工业大学郑柳春团队欢迎化学化工、高分子化学或有机合成方向的博士生和硕士生加入
已经有5人回复
2025冷门绝学什么时候出结果
已经有7人回复
请问有评职称,把科研教学业绩算分排序的高校吗
已经有6人回复
Bioresource Technology期刊,第一次返修的时候被退回好几次了
已经有7人回复
请问下大家为什么这个铃木偶联几乎不反应呢
已经有5人回复
康复大学泰山学者周祺惠团队招收博士研究生
已经有6人回复













回复此楼