*** ERROR ***                           CP =     651.086   TIME= 15:22:31
TB,MISO table for material 1 at temperature 0 has a tangent slope value
less than zero.
我建立的模型是和混凝土有关的,计算时出现以上错误直接不能计算,网上说是第一点的斜率要等于定义的弹性模量,还有曲线的斜率不能大于定义的ex,可是这些都满足啊混凝土部分的命令如下,麻烦大神帮分析分析啊
ET,1,SOLID65
MP,EX,1,13585
MP,PRXY,1,0.2
KEYOPT,1,1,0
KEYOPT,1,7,1
FC=14.3
FT=1.43
TB,CONCR,1
TBDATA,,0.5,0.95,FT,FC
TB,MISO,1,,11
TBPT,,0.0002,FC*0.19
TBPT,,0.0004,FC*0.36
TBPT,,0.0006,FC*0.51
TBPT,,0.0008,FC*0.64
TBPT,,0.0010,FC*0.75
TBPT,,0.0012,FC*0.84
TBPT,,0.0014,FC*0.91
TBPT,,0.0016,FC*0.96
TBPT,,0.0018,FC*0.99
TBPT,,0.002,FC
TBPT,,0.0033,FC*0.85
回复此楼
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖

wxt5288

新虫 (初入文坛)

采用mkin后还是出错
你好,地球
13楼2015-12-23 15:37:45
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖
查看全部 14 个回答

yh8910

铁虫 (小有名气)

【答案】应助回帖

感谢参与,应助指数 +1
意思就是所定义的应力应变曲线的斜率不能小于0,不能有下降段。
2楼2014-10-07 17:18:55
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖

nanquangg

金虫 (初入文坛)

引用回帖:
2楼: Originally posted by yh8910 at 2014-10-07 17:18:55
意思就是所定义的应力应变曲线的斜率不能小于0,不能有下降段。

我知道是什么意思,就是不知道为什么会报这个错啊
3楼2014-10-07 18:38:53
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖

yh8910

铁虫 (小有名气)

引用回帖:
3楼: Originally posted by nanquangg at 2014-10-07 18:38:53
我知道是什么意思,就是不知道为什么会报这个错啊...

你的最后三个命令流
TBPT,,0.0018,FC*0.99
TBPT,,0.002,FC
TBPT,,0.0033,FC*0.85
出现了下降段。
4楼2014-10-08 09:03:30