| 查看: 172 | 回复: 0 | ||
[求助]
有高手可以翻译下这段吗?
|
|
Drug penetration through the biological barrierTo construct chromatographic models simulating biological barriers, different stationary materials have been tested. To begin with, most studies were performed by RP-HPLC on octadecyl silica [10–13]. These chromatographic systems enabled correlations between logarithms of partition coefficients in n-octanol-water partition system, log Po/wand chromatographic data (log kw or log k) to be obtained. Therefore, chromatographic retention parameters, as a result of adsorptionpartitioning phenomenon in RP systems, are regarded as lipophilicity descriptors of drugs. In the 1990s, Pidgeon’s group revealed a correlation between the chromatographic retention on immobilized artificial membranes (IAMs) formed by covalently bound lecithin to propylamine silica and their ability to predict human skin permeation [14]. Currently, a new generation of IAM-type columns with immobilized phosphatidylcholine or sphingomyelin that simulate the structure of cell membranes [15,16]are at researchers’ disposal. Such chromatographic systems can be considered as an ‘in vivo’ model of cellular barrier transgression by the drug. The cholesterol-bonded phase, owing to its similarity to immobilized artificial membranes, also enables utilization of chromatographic data to anticipate the process of the cell membrane permeation. Retention on the cholesterol column, as a combination of different interactions of analytes with the surface, reflects the so-called ‘phospholipophilicity’ of drugs. However, retention measured by IAM columns does not frequently depend linearly on the composition of the mobile phase as in conventional RP systems. Therefore, slight differences in the content of the organic solvent in the eluent will determine the quality of retention–activity relationships [17]. MLC also provides a fairly good model for in vivodrug partitioning. It has been demonstrated that RP-HPLC with micellar eluents credibly reflects complex interactions of drugs with their biological target. The problem of these assays includes high concentrations of surfactants and buffers that may damage the column. One solution is the use of ionic liquids with a small NaCl addition achieving micelle concentration in dilute solutions [18]. This proposal is worth considering, especially since MLC is the only technique that allows direct injection of serum samples. |
» 猜你喜欢
基金委咋了?2026年的指南还没有出来?
已经有5人回复
国自然申请面上模板最新2026版出了吗?
已经有17人回复
纳米粒子粒径的测量
已经有8人回复
疑惑?
已经有5人回复
计算机、0854电子信息(085401-058412)调剂
已经有5人回复
Materials Today Chemistry审稿周期
已经有5人回复
溴的反应液脱色
已经有7人回复
推荐一本书
已经有12人回复
基金申报
已经有4人回复
常年博士招收(双一流,工科)
已经有4人回复
找到一些相关的精华帖子,希望有用哦~
HPLC标准品和文献报导的出峰时间偏移了1分钟正常不?
已经有9人回复
两篇关于用HPLC分离制备红霉素很老的文献
已经有3人回复
从文献上看到HPLC流动相用到磷酸盐(pH2.3),但不知道准确的配制方法,请高手指点一下
已经有4人回复
科研从小木虫开始,人人为我,我为人人











回复此楼
点击这里搜索更多相关资源