| ²é¿´: 676 | »Ø¸´: 1 | |||
½Ñôľ³æ (СÓÐÃûÆø)
|
[ÇóÖú]
Éó¸åÈËÌáÎÊ£ºÎªÊ²Ã´ÔÚ0.1M KOHÈÜÒºÀï²â·ÇøÆÏÌÑÌÇ´«¸ÐÆ÷£¬¶ø²»ÔÚÖÐÐÔÈÜÒºÀï²â£¿ ÒÑÓÐ1È˲ÎÓë
|
|
×î½üһƪ¹ØÓÚÑõ»¯ÍµÄÐÂ×÷£¬Éó¸åÈËÌáÁËÒ»¸öÎÊÌ⣺The electrochemical performance of the CuO nanotube electrode as non-enzymatic glucose biosensor was investigated in 0.1 M KOH solution. However, the pH of this solution is about 13 which is far from 7.35~7.45 of normal human blood. Why not conduct the experiments in a condition close to a physiological pH? Õâ¸öÎÊÌâ¸ÃÔõô»Ø´ð£¿ÊÇÈÃÎÒ²¹×öʵÑéÂ𣿠|
» ²ÂÄãϲ»¶
0703µ÷¼Á
ÒѾÓÐ4È˻ظ´
1
ÒѾÓÐ21È˻ظ´
ÎïÀí»¯Ñ§ÂÛÎÄÈóÉ«/·ÒëÔõôÊÕ·Ñ?
ÒѾÓÐ126È˻ظ´
0703 µ÷¼Á
ÒѾÓÐ6È˻ظ´
ÕÐÊÕ
ÒѾÓÐ0È˻ظ´
Î÷ÄÏij211ÕÐ27½ì²©Ê¿
ÒѾÓÐ32È˻ظ´
´óÁ¬¹¤Òµ½ÜÇà/³¤½ÍŶÓ-ÉúÎïÖʲÄÁÏ-´¢ÄÜµç³Ø·½ÏòÕÐÊÕ2026¼¶²©Ê¿Éú
ÒѾÓÐ0È˻ظ´
Çóµ÷¼ÁÒ»Ö¾Ô¸º£´ó£¬0703»¯Ñ§Ñ§Ë¶304·Ö£¬Óдó´´ÏîÄ¿£¬Ëļ¶Òѹý
ÒѾÓÐ10È˻ظ´
070300 Çóµ÷¼Á
ÒѾÓÐ1È˻ظ´
ÉîÛÚ´óѧ¸ßµÈÑо¿ÔºÕÔΰ¿ÎÌâ×éÕÐÊÕ»¯Ñ§µ÷¼ÁÉú
ÒѾÓÐ3È˻ظ´
ϰ»Éù
ľ³æ (ÕýʽдÊÖ)
- Ó¦Öú: 33 (СѧÉú)
- ½ð±Ò: 3827.4
- É¢½ð: 1266
- ºì»¨: 8
- Ìû×Ó: 689
- ÔÚÏß: 415.8Сʱ
- ³æºÅ: 1113710
- ×¢²á: 2010-10-04
- ÐÔ±ð: MM
- רҵ: µç»¯Ñ§·ÖÎö
¡¾´ð°¸¡¿Ó¦Öú»ØÌû
¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï
¸Ðл²ÎÓ룬ӦÖúÖ¸Êý +1
½Ñô: ½ð±Ò+20, ¡ï¡ï¡ï¡ï¡ï×î¼Ñ´ð°¸, ·Ç³£¸ÐлÄúµÄÈÈÐİïÖú£¡ 2014-09-11 08:52:36
¸Ðл²ÎÓ룬ӦÖúÖ¸Êý +1
½Ñô: ½ð±Ò+20, ¡ï¡ï¡ï¡ï¡ï×î¼Ñ´ð°¸, ·Ç³£¸ÐлÄúµÄÈÈÐİïÖú£¡ 2014-09-11 08:52:36
| Èç¹ûÂ¥Ö÷µÄ²ÄÁÏ¿ÉÒÔÔÚÖÐÐÔÈÜÒºÀï¼ì²âÆÏÌÑÌÇ£¬¿ÉÒÔ²¹Ò»ÏÂʵÑ飬֤Ã÷²ÄÁÏ¿ÉÒÔÓ¦ÓÃÓÚʵ¼ÊÉúÎïÑùÆ·µÄ²â¶¨¡£Èç¹ûÔÚÖÐÐÔÈÜÒºÖÐûÓзåÐÍ£¬ÄÇô¾Í¿ÉÒÔ½âÊÍһϣ¬Ò»°ãµÄÆÏÌÑÌǵļì²â¶¼ÊÇÔÚ¼îÐÔÌõ¼þϽøÐе쬏ø³öһЩÔÚ¼îÐÔÌõ¼þϼì²âÆÏÌÑÌǵÄÒýÎÄ¡£ µ±È»£¬Ö»ÊÇÎÒ¸öÈ˵ÄÒâ¼û£¬½ö¹©²Î¿¼¡£ |

2Â¥2014-09-03 10:42:48













»Ø¸´´ËÂ¥