2. Unsatisfactory tensile test specimens (excluding pipes)
2.1 Individual tests
For each unsatisfactory tensile specimen, two substitute specimens shall be tested, which shall be taken from the same test section as the original specimen, or from the same sample. In every case, both specimens shall satisfy the requirements.
2.2 Testing by heats or batches
The manufacturer shall have the option of separating the sample which has yielded unsatisfactory results or of continuing to treat it as part of the unit test quantity.
If the sample in question is separated, then, for each unsatisfactory tensile specimen, two substitute specimens shall be tested which shall be taken from different samples of the unit test quantity.
If the sample in question continues to be treated as part of the unit test quantity, one of the retests shall be performed on this sample and the other on a different sample.
Both retests shall satisfy the requirements.
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖

篮球王者

新虫 (初入文坛)

【答案】应助回帖

High strength Ni–Zr binary ultrafine eutectic-dendrite composite with large
plastic deformability
3楼2014-07-17 09:59:25
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖
查看全部 3 个回答

reko34

木虫 (正式写手)

【答案】应助回帖

★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ...
真强必胜: 金币+3, 多谢 2014-07-17 12:33:37
huangguaha: 金币+100, 翻译EPI+1, ★★★★★最佳答案, 非常感谢 2014-07-17 13:41:20
2. 不满意的拉伸试件(不包括管)
2.1 单件试验
对每个不满意的拉伸试件,应测试2个替补样件,替补样件取自与原样件相同的试验段或来自同一个样本。不论哪种情况,2个替补样件必需都满足要求。
2.2 热或批量试验
制造商可选择将得出不满意结果的样本分离或继续将其视为单元测试量的一部分。
如果选择将问题样件分离,对每个不满意的拉伸试件,取单元测试量的2个不同样本作为替补样件进行测试。
如果将问题样件继续视为单元测试数量的一部分,在该样件上进行一次重复试验,在另一个样件进行另一次。
2次重复试验都必需满足要求。