[求助] Ag/AgCl做参比电极,待测液中必须有氯离子吗???? 已有6人参与

刚投一篇关于电化学传感器的文章,其中一个审稿意见是:Ag/AgCl做参比电极,待测液中没有Cl-, 参比电极如何保持电压稳定???我的体系中使用PBS作为电解液,PBS中只是用磷酸氢二钠和磷酸二氢钠配制的,没有加盐。请教各位,使用Ag/AgCl做参比电极,与电解液中是否有Cl-有关系吗?谢谢~
回复此楼

» 收录本帖的淘帖专辑推荐

锂电-电化学

» 猜你喜欢

» 本主题相关价值贴推荐,对您同样有帮助:

已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖

mychtsh126

金虫 (小有名气)

引用回帖:
3楼: Originally posted by binbinitaly at 2014-07-08 12:05:07
我觉得审稿人的意思是如果溶液中没有氯离子的话会造成的比较大的液接电势,可能会对测试结果造成影响,这个液接电势可以用盐桥来减小

According to the methods section (p. 5), the phosphate buffer solution (PBS) used is 0.02 M, and contains only forms of sodium phosphate. This seems problematic when used with a Ag/AgCl reference electrode, as Cl- is necessary for stable potential application. How can this work? Are the results the same with Cl- present, for example if the studies were done in “phosphate buffered saline” (which is the usual solution defined by the abbreviation “PBS”), which contains 0.9% NaCl.
这是审稿人的意见,我和楼主理解是一样的,所以想在加盐的PBS中再测一下,证明没有影响。
关于盐桥,我也查了些资料,是不是参比电极的顶端就是一个盐桥??还是在测试体系中建一个盐桥??半路进入电化学领域的,所以基础很差,谢谢解答~
6楼2014-07-08 15:22:04
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖
查看全部 17 个回答

wangyongyl

木虫 (正式写手)

【答案】应助回帖

★ ★ ★
感谢参与,应助指数 +1
mychtsh126: 金币+3, ★★★很有帮助 2014-07-08 15:14:35
和溶液中cl离子关系不大吧。。。。
Ag/AgCl做参比电极,待测液中必须有氯离子吗????
IMG_20140708_0953301.jpg

你的幸福由我独家赞助!
2楼2014-07-08 10:04:04
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖

binbinitaly

铁杆木虫 (著名写手)

【答案】应助回帖

★ ★ ★ ★ ★
感谢参与,应助指数 +1
mychtsh126: 金币+5, ★★★★★最佳答案 2014-07-08 15:15:52
我觉得审稿人的意思是如果溶液中没有氯离子的话会造成的比较大的液接电势,可能会对测试结果造成影响,这个液接电势可以用盐桥来减小
既然选择了远方,便只顾风雨兼程!时间是检验一切的唯一标准!
3楼2014-07-08 12:05:07
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖

dajiangyou

铜虫 (小有名气)

如果审稿人的确是这个意思的话,你就建议他先补下电化学基础