24小时热门版块排行榜    

查看: 92  |  回复: 2
当前主题已经存档。
【悬赏金币】回答本帖问题,作者dashan_612将赠送您 5 个金币

dashan_612

木虫 (正式写手)

[求助] 求一张纯Si的红外扫描图

样品在Si上面作的,首先要做的就是把Si放在那里扫描一下背底的光谱,然后在测试样品的光谱。现在我就是想要一张标准的Si的红外光谱,谢谢

» 猜你喜欢

已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖

agct

金虫 (正式写手)

We then began to investigate the reliability of the supplied IR measurements. One of the authors, G. Forster, noted the transparency of the silicon crystal to IR radiation. Then, we surmised that the experimental technique and the data obtained might be suspect. Our suspicion was further reinforced when we reviewed the literature on the radiative properties of silicon crystals in the infrared region of the spectrum (see Figures 2 and 3). The steep variations in these properties, particularly in the infrared region, and the corrections needed to account for the transmittance and reflectance of silicon seem to preclude unaided and direct thermometric measurement of the silicon crystal. Another author, A. Khounsary, suggested that the silicon crystal be coated with a layer of a material opaque to infrared.



Figure 2: Normal Spectral Reflectance of Silicon [6].









Figure 3: Normal Spectral Transmittance of Silicon [6].


The IR scanner (Inframetrics model 525) used at Cornell is an "8-12" unit. This means that it is most sensitive to and suitable for (blackbody) temperature measurements in the 20-100°C range. Unfortunately, it is in this very range that a silicon crystal exhibits steep variations in its radiative properties. Therefore, if the crystal is not coated, the row data taken by the infrared scanner must be processed and interpreted to infer the actual temperatures, a laborious (and unnecessary) task in view of the strong frequency dependence of the radiative properties of silicon crystals in the spectral range of interest. On the basis of these considerations, it was then decided to run some temperature measurement tests at the ANL/Bldg. 223 laboratory. Experimental apparatus consisting of a piece of spare silicon crystal with a Peltier-effect back was set up. A thermocouple was also contact-mounted on the frontal surface of the crystal to independently measure the surface temperature at that location.

Inframetrics, Inc., was contacted to seek advice on possible opaque coatings. They suggested black vinyl electrician's tape, spray foot powder, and dye penetrant developer powder; in addition, we also considered carbon black and candle soot as acceptable candidates. These materials are all opaque to infrared radiation, have emissivities in excess of 0.9 and are readily available. The black electrician's tape and the dye penetrant developer powder (in patches) were used in our experiment. Both were equally practical, but the tape would lose its adhesiveness and peel off at higher operating temperatures. The thermocouple itself was also coated so that its temperature would also be monitored to assure proper surface contact, and thus accurate reading of the surface temperature.

Our preliminary experimental data indicated a linear correlation between the IR scanner readings and the thermocouple measurements.

As a result of these experiments, therefore, we believe that the source of the three-fold difference between our thermal-hydraulic modeling results and the Cornell IR temperature measurements are due to erroneous interpretation of the IR readings. The actual temperature rise along the surface of the three-channel crystal is about three times the values presented at the March 11 meeting. Thus, the correct value is in the 40-45°C range (assuming that the flow rate, channel and footprint dimensions, power level, etc. that are provided are accurate).

Follow-up IR calibration studies in the laboratory and accompanying analytical work verified the above conclusions. This follow-up work is detailed below.
/╲____╱\ /ˊ ` \ | ╭╮ ╭╮ | |( )( )| \/ / · \ \/ │ | – | │
2楼2008-03-08 12:54:26
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖

dashan_612

木虫 (正式写手)

没有实验扫描结果么
3楼2008-03-08 21:50:18
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖
相关版块跳转 我要订阅楼主 dashan_612 的主题更新
不应助 确定回帖应助 (注意:应助才可能被奖励,但不允许灌水,必须填写15个字符以上)
最具人气热帖推荐 [查看全部] 作者 回/看 最后发表
[考研] 085600材料与化工306 +4 z1z2z3879 2026-03-21 4/200 2026-03-21 23:44 by ms629
[考研] 一志愿北京化工大学070300 学硕336求调剂 +3 vv迷 2026-03-21 4/200 2026-03-21 23:05 by f19980501
[考研] 考研化学学硕调剂,一志愿985 +5 张vvvv 2026-03-15 7/350 2026-03-21 19:23 by ColorlessPI
[考研] 306求0703调剂一志愿华中师范 +5 纸鱼ly 2026-03-21 5/250 2026-03-21 17:11 by 学员8dgXkO
[考研] 26考研一志愿中国石油大学(华东)305分求调剂 +6 嘉年新程 2026-03-15 6/300 2026-03-21 17:07 by Dream007008
[考研] 一志愿山大07化学 332分 四六级已过 本科山东双非 求调剂! +3 不想理你 2026-03-16 3/150 2026-03-21 03:59 by JourneyLucky
[考研] 307求调剂 +3 wyyyqx 2026-03-17 3/150 2026-03-21 03:20 by JourneyLucky
[考研] 一志愿华中科技大学,080502,354分求调剂 +5 守候夕阳CF 2026-03-18 5/250 2026-03-21 01:06 by JourneyLucky
[考研] 材料专业求调剂 +6 hanamiko 2026-03-18 6/300 2026-03-21 00:24 by JourneyLucky
[考研] 296求调剂 +6 www_q 2026-03-18 10/500 2026-03-20 23:56 by JourneyLucky
[考研] 274求调剂 +10 S.H1 2026-03-18 10/500 2026-03-20 23:51 by JourneyLucky
[考研] 材料与化工 322求调剂 +4 然11 2026-03-19 4/200 2026-03-20 22:12 by luoyongfeng
[考研] 290求调剂 +7 ^O^乜 2026-03-19 7/350 2026-03-20 21:43 by JourneyLucky
[考研] 工科材料085601 279求调剂 +7 困于星晨 2026-03-17 9/450 2026-03-20 17:38 by 无懈可击111
[考研] 320求调剂0856 +3 不想起名字112 2026-03-19 3/150 2026-03-19 22:53 by 学员8dgXkO
[考研] 085601专硕,总分342求调剂,地区不限 +5 share_joy 2026-03-16 5/250 2026-03-18 14:48 by haxia
[考研] 275求调剂 +4 太阳花天天开心 2026-03-16 4/200 2026-03-17 10:53 by 功夫疯狂
[考研] 283求调剂 +3 听风就是雨; 2026-03-16 3/150 2026-03-17 07:41 by 热情沙漠
[考研] 机械专硕325,寻找调剂院校 +3 y9999 2026-03-15 5/250 2026-03-16 19:58 by y9999
[考研] 070300化学学硕求调剂 +6 太想进步了0608 2026-03-16 6/300 2026-03-16 16:13 by kykm678
信息提示
请填处理意见