| The confluent cells were incubated in serum-free medium for 30 min followed by the addition of 50,000-100,000 cpmcpm of 125I-labeled human growth hormone (hGH) |
» 猜你喜欢
交叉科学部支持青年基金,对三无青椒是个机会吗?
已经有4人回复
招博士
已经有6人回复
限项规定
已经有8人回复
国家基金申请书模板内插入图片不可调整大小?
已经有5人回复
国家级人才课题组招收2026年入学博士
已经有5人回复
Fe3O4@SiO2合成
已经有6人回复
青年基金C终止
已经有4人回复
青椒八年已不青,大家都被折磨成啥样了?
已经有7人回复
为什么nbs上溴 没有产物点出现呢
已经有10人回复
救命帖
已经有11人回复
» 本主题相关价值贴推荐,对您同样有帮助:
2楼2014-02-27 17:55:01
3楼2014-02-27 18:29:18
wizardfan
至尊木虫 (著名写手)
- BioEPI: 18
- 应助: 599 (博士)
- 贵宾: 1.818
- 金币: 24632.2
- 散金: 197
- 红花: 48
- 沙发: 2
- 帖子: 2254
- 在线: 400.7小时
- 虫号: 1879241
- 注册: 2012-07-05
- 性别: GG
- 专业: 生物信息学
【答案】应助回帖
感谢参与,应助指数 +1
|
和放射有关的就是counts per minute The measurement of ionizing radiation is sometimes expressed as being a rate of counts per unit time registered by a radiation monitoring instrument, of which counts per minute and counts per second are commonly used. This measurement is only of the rate of events registered by the measuring instrument, not the rate of events at the point of original emission. For radioactive decay measurements it must not be confused with disintegrations per unit time (dpm), which represents the rate of atomic disintegration events at the source of the radiation. Count rates are normally associated with the measurements of particles, such as alpha particles and beta particles. For gamma ray and X-ray dose measurements a unit such as the Sievert is normally used |
4楼2014-02-28 06:23:45
yipan
铜虫 (职业作家)
- BioEPI: 2
- 应助: 214 (大学生)
- 金币: 15976.4
- 散金: 275
- 红花: 6
- 帖子: 4122
- 在线: 195.9小时
- 虫号: 2743878
- 注册: 2013-10-22
- 性别: GG
- 专业: 整合生物学
5楼2014-02-28 10:13:58
6楼2014-03-18 21:20:14
7楼2014-03-18 21:22:09
fightcricket
金虫 (正式写手)
- 应助: 4 (幼儿园)
- 金币: 694.3
- 散金: 30
- 红花: 1
- 帖子: 414
- 在线: 263.3小时
- 虫号: 972848
- 注册: 2010-03-16
- 专业: 细胞信号转导
8楼2014-03-20 07:13:42
fightcricket
金虫 (正式写手)
- 应助: 4 (幼儿园)
- 金币: 694.3
- 散金: 30
- 红花: 1
- 帖子: 414
- 在线: 263.3小时
- 虫号: 972848
- 注册: 2010-03-16
- 专业: 细胞信号转导
|
虽然关了贴,但我想补一段。 Disintegrations per minute (dpm) and disintegrations per second are measures of the intensity of the source of radioactivity. The SI unit of radioactivity, the becquerel, is equivalent to one disintegration per second. It is included in this article to show that it should not be confused with cpm. Becquerels is the strength of the source of radiation, but cpm is the number of counts received by an instrument from that source. The efficiency of the radiation detector (e.g. scintillation counter) and its relative position to the source of radiation must be accounted for when relating cpm to dpm. Dpm is the number of atoms that have decayed, not the number of atoms that have been measured as decayed. SI Units for radioactive disintegration[edit] One becquerel (Bq) is equal to one disintegration per second; 1 becquerel (Bq) is equal to 60 dpm. One curie (Ci) is equal to 3.7×1010 Bq or dps, which is equal to 2.22×1012 dpm. 这才完整。 |