24小时热门版块排行榜    

查看: 1394  |  回复: 19
当前只显示满足指定条件的回帖,点击这里查看本话题的所有回帖

杨大松

至尊木虫 (文坛精英)

[求助] HRESI-TOF 正离子 内标,谢谢

HRESI-TOF 正离子谱上有分子量为502.2066的峰,为内标峰,请问是什么化合物。
回复此楼
碧雪清谭
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖

lzjessie_wlf

金虫 (小有名气)

杨大松: 回帖置顶 2012-12-21 08:51:17
引用回帖:
12楼: Originally posted by 杨大松 at 2012-12-20 08:15:38
这个我昨天看到了,google上搜出来的吧,我还scidinder了这个分子式,有1438个化合物,我想着可能不难,因为标准物质肯定有什么特点人家才选用来做参考的。不可能是什么化合物都可以,所以做的人应该知道,还是感谢 ...

The normal internal standard for calculating the MS machine should be commercial available, stable and detectable in both positive and negative mode.
  C25H29N5O5Na is the sodium adduct of WFQ peptide. But, I never use it, normally we use Leucine enkephalin with M+H 556.2771 and M-H 554.2615 as internal standard for calculating the small molecules around the molecular weight. Some person also use the characterized compound from the sample submitter for calculating the same serial of their samples.
  Bunches of internal standard have been explored as internal standard from inorganic compounds like Naformate complex,drugs, pepetide, proteins, and glycan.........
  If the MS operator do not known what the standard is, asking the vendors related to MS facility will give an clue to find out what the 502.2066 is.

» 本帖已获得的红花(最新10朵)

17楼2012-12-21 00:32:54
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖
查看全部 20 个回答

organicsuper

木虫 (正式写手)

【答案】应助回帖

感谢参与,应助指数 +1
那你要问做质谱的老师,
2楼2012-12-19 17:12:19
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖

杨大松

至尊木虫 (文坛精英)

引用回帖:
2楼: Originally posted by organicsuper at 2012-12-19 17:12:19
那你要问做质谱的老师,

她不知道。
碧雪清谭
3楼2012-12-19 17:13:53
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖

organicsuper

木虫 (正式写手)

她拿东西来做内标,居然不知道啥东西,只知道分子量哈.
4楼2012-12-19 18:02:38
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖
信息提示