| 查看: 1827 | 回复: 19 | |||
keepstrong铜虫 (初入文坛)
|
[交流]
AMM已经检索到V214,中间201-202跳检。 已有11人参与
|
||
|
跟大家一样很关心检索进度,一卷一卷随机抽文章查,确定AMM已经检索到V214,中间201-202跳检,不知道什么时候补检。 不过马上就到215-216了,希望这周能出来,加油! |
» 本帖已获得的红花(最新10朵)
» 猜你喜欢
假如你的研究生提出不合理要求
已经有4人回复
论文终于录用啦!满足毕业条件了
已经有27人回复
所感
已经有3人回复
要不要辞职读博?
已经有7人回复
不自信的我
已经有11人回复
北核录用
已经有3人回复
实验室接单子
已经有3人回复
磺酰氟产物,毕不了业了!
已经有8人回复
求助:我三月中下旬出站,青基依托单位怎么办?
已经有10人回复
26申博(荧光探针方向,有机合成)
已经有4人回复

keepstrong
铜虫 (初入文坛)
- 应助: 0 (幼儿园)
- 金币: 76.5
- 帖子: 15
- 在线: 1.7小时
- 虫号: 2171856
- 注册: 2012-12-04
- 性别: GG
- 专业: 制造系统与自动化
★
杈杈: 金币+1, 感谢提供检索信息! 2012-12-10 10:57:12
杈杈: 金币+1, 感谢提供检索信息! 2012-12-10 10:57:12
|
已捡,恭喜你 Accession number: 20124815724661 Title: Application of precision time protocol on networked control systems Authors: Yang, Chuanshun1 ; Kong, Xiangying1 Author affiliation: 1 Jiangsu Automation Research Institute, Lianyungang, 222006, China Corresponding author: Yang, C. (yang97718@yahoo.com.cn) Source title: Applied Mechanics and Materials Abbreviated source title: Appl. Mech. Mater. Volume: 203 Monograph title: Review of Modern Engineering Solutions for the Industry Issue date: 2012 Publication year: 2012 Pages: 192-197 Language: English ISSN: 16609336 ISBN-13: 9783037854921 Document type: Conference article (CA) Conference name: 2012 International Conference on Mechatronic Systems and Automation Systems, MSAS 2012 Conference date: July 21, 2012 - July 21, 2012 Conference location: Wuhan, China Conference code: 93982 Sponsor: Information Technology and Industrial Engineering Research Center Publisher: Trans Tech Publications, P.O. Box 1254, Clausthal-Zellerfeld, D-38670, Germany Abstract: In order to overcome the problem of the clock synchronization accuracy between scattered nodes was not high on traditional networked control systems, proposed a new method of using the IEEE 1588 standard for precision time protocol. First studied the principle and algorithm of precision time protocol, the best master clock algorithm and timestamp detection methods. Then presented the timestamp detection method with the use of software and hardware on networked control systems to improve clock synchronization accuracy, and analyzed the feasibility of the method in theory. Finally, tested accuracy of the clock synchronization, and the test results showed that synchronization accuracy can reach nanosecond, can meet the application requirements of the networked control systems. © (2012) Trans Tech Publications, Switzerland. Number of references: 11 Main heading: Networked control systems Controlled terms: Algorithms - Automation - Hardware - Mechanical clocks - Standards Uncontrolled terms: Application requirements - Clock Synchronization - Detection methods - Hardware-assisted - IEEE 1588 - Master clock - Time-stamp Classification code: 943.3 Special Purpose Instruments - 921 Mathematics - 902.2 Codes and Standards - 732 Control Devices - 731 Automatic Control Principles and Applications - 723 Computer Software, Data Handling and Applications - 605 Small Tools and Hardware DOI: 10.4028/www.scientific.net/AMM.203.192 Database: Compendex Compilation and indexing terms, © 2012 Elsevier Inc |

5楼2012-12-07 23:52:25
3楼2012-12-07 17:38:13

2楼2012-12-07 14:25:58
yang97718
新虫 (小有名气)
- 应助: 1 (幼儿园)
- 金币: 4736.8
- 红花: 2
- 帖子: 119
- 在线: 205.6小时
- 虫号: 2024375
- 注册: 2012-09-23
- 专业: 代数学
4楼2012-12-07 20:15:26
6楼2012-12-08 11:30:23
7楼2012-12-08 21:23:12
送鲜花一朵
|
8楼2012-12-08 21:46:39

9楼2012-12-10 15:06:24
aomy_ren
木虫 (小有名气)
- 应助: 1 (幼儿园)
- 金币: 1739.6
- 红花: 1
- 帖子: 58
- 在线: 22.2小时
- 虫号: 2181191
- 注册: 2012-12-12
- 性别: GG
- 专业: 制造系统与自动化

10楼2012-12-12 00:39:19












回复此楼