| 查看: 1574 | 回复: 4 | |||
| 当前只显示满足指定条件的回帖,点击这里查看本话题的所有回帖 | |||
[交流]
【求助】美国药典中一段原文的翻译问题
|
|||
|
请大家受累给翻译下 55 BIOLOGICAL INDICATORS—RESISTANCE PERFORMANCE TESTS D-VALUE DETERMINATION Conduct all the tests described in this section under aseptic conditions, using sterilized equipment for nonthermophilic microorganisms. D-value determination for G. stearothermophilus and B. coagulans can be performed in a controlled but unclassified environment. Apparatus The test equipment for the determination of microbial resistance is described in substantial detail in ISO 18472, Sterilization of Health Care Products—Biological and Chemical Indicators—Test Equipment.1 The details of individual Biological Indicator Evaluation Resistometers (BIERs) vary with the specifics of their design and the particular sterilization process in conjunction with which they are used. Provided that the performance of the BIER vessel meets the requirements of the ISO standard for exposure of the biological indicator, design differences are acceptable. Procedure Carry out the tests for D value at each of the applicable sets of sterilization conditions for which the packaged biological indicator under test is labeled for use. Take a sufficient number of groups of specimens of biological indicators in their original individual containers, each group consisting of not less than 5 specimens. The number of groups provides a range of observations from not less than one labeled D value below the labeled survival time through not less than one labeled D value above the labeled kill time. Place each group on a separate suitable specimen holder that permits each specimen to be exposed to the prescribed sterilizing condition at a specific location in the sterilizing chamber of the BIER. Check the BIER apparatus for operating parameters using specimen holders without specimens. Select a series of sterilizing times in increments from the shortest time for the specimens to be tested. The differences in sterilizing times over the series are as constant as feasible, and the difference between adjacent times is no greater than 75% of the labeled D value. |
» 猜你喜欢
垃圾破二本职称评审标准
已经有18人回复
职称评审没过,求安慰
已经有53人回复
毕业后当辅导员了,天天各种学生超烦
已经有5人回复
26申博自荐
已经有3人回复
A期刊撤稿
已经有4人回复
EST投稿状态问题
已经有7人回复
» 抢金币啦!回帖就可以得到:
郑州大学招收2026年外科学博士研究生
+1/462
Analytical Science Advances 征稿中
+1/180
湖南师范大学蒋乐勇教授课题组招收2026届“申请-考核”制博士生
+1/175
复旦大学化学系杰青/优青团队诚聘博士后
+3/150
Analytical Science Advances(Wiley出版社)长期征稿中...
+1/87
山东第二医科大学和广州中医药大学药学硕士招生
+1/84
中国科学院化学研究所招收2026级博士生
+5/75
博士后招聘
+1/28
人到中年,还能干啥
+1/21
肿瘤免疫课题组招聘 博后
+1/14
北理工柔性电子国家杰青团队招博士后及科研助理
+1/9
海南师范大学招收化学博士(光电功能材料课题组招收博士研究生)
+1/8
想读博士(理工/化学类/新能源材料)求大佬捞一下 ?或者师兄师姐推荐/建议博导招生信息
+1/8
海南师范大学招收化学博士(光电功能材料课题组招收博士研究生)
+1/6
武汉理工大学胡老师课题组招收2026年博士研究生
+1/4
南京大学FinTech大模型实验室招募斯坦福国际联培博士生(2026)
+1/2
长春工业大学 机电工程学院 韩玲教授 招收审核制2026年秋季入学博士生
+1/1
同济大学电信学院,肖李课题组招收2026年统考硕士生1-2名。
+1/1
中国科大电池方向任晓迪课题组招收2026级博士生-电解液/电池安全性/人工智能方向
+1/1
长安大学罗刚课题组招聘科研助理-隧道通风/爆破相关研究方向
+1/1
|
本帖内容被屏蔽 |
3楼2011-03-05 12:43:57
|
55 生物指标 — — 电阻性能测试 D 值的确定 进行此使用 nonthermophilic 微生物的消毒的设备的无菌条件下一节中描述的所有测试。G.嗜热脂肪和 B.凝结 D 值测定可以控制但未分类的环境中执行。 仪器 细菌耐药测定试验设备 ISO 18472,卫生保健产品的消毒大量详细介绍 — — 生物和化学指标 — — 随具体的设计和在一起,它们用于特定的灭菌过程的测试 Equipment.1 个人生物指标评价表征 (BIERs) 的详细信息。只要棺材容器的性能符合 ISO 标准的生物指示器的暴露,接受设计上的差异。 过程 进行测试,在每个适用的集杀菌条件的情况下,测试下打包的生物指示器标记为使用 D 值。每个小组,成员包括不少于 5 个标本采取足够数量的标本的生物指标在他们原来的单个容器中的组。组的数量提供一系列的意见不小于一个标有 D 值低于通过上面的标记的杀时间不少于一个标记 D 值的标记的生存时间。持有单独适用的标本,允许每个样品暴露于订明的杀菌条件消毒室棺材的某一特定位置上放置每个组。检查操作的参数,使用无标本的标本持有柩仪。选择一系列的消毒时间从最短的时间,要测试样品的增量。消毒时间系列的差异是可行的话,为不断,不应超过 75%的标记的 D 值相邻的时间之间的差值。 |
4楼2011-03-05 16:51:31
5楼2011-03-06 21:20:36













回复此楼