| ²é¿´: 551 | »Ø¸´: 2 | |||
| ±¾Ìû²úÉú 1 ¸ö ·ÒëEPI £¬µã»÷ÕâÀï½øÐв鿴 | |||
[½»Á÷]
Á½¾ä»°·Òë³ÉÓ¢ÎÄ ¹Ø¼ü´Ê¾ùÌṩ¡£
|
|||
| ±¾ÎÄÑо¿Ãܼä¸ôµçλ·¨£¨CIPS£©²âÁ¿¹ý³ÌÖкãµçλÒÇ£¨constant potential rectifier£©µçѹ/µçÁ÷Êä³ö£¨voltage/current output) ¼°ÂñµØ¹ÜµÀ(buried pipeline) ¹Ü/µØµçλ(pipe-to-soil potential) ËæµçÁ÷ÖÐ¶ÏÆ÷( current interrupter) ͨ¶ÏÖÜÆÚ (ON/OFF cycle) µÄ±ä»¯£¬Í¬Ê±Ò²ÏµÍ³²ûÊöÁËÔÚÏÖÓÐÒõ¼«±£»¤ÏµÍ³(cathodic protection system)϶ϵçÖÜÆÚ(Off cycle)µÄºÏÀíÉèÖü°Í¨µçÖÜÆÚ(On cycle)¶Ô¹Ü/µØ¼äͨ/¶Ïµçµçλ(ON/OFF potential) µÄÓ°Ïì¡£ |
» ²ÂÄãϲ»¶
293Çóµ÷¼Á
ÒѾÓÐ12È˻ظ´
070300»¯Ñ§319Çóµ÷¼Á
ÒѾÓÐ4È˻ظ´
268Çóµ÷¼Á
ÒѾÓÐ9È˻ظ´
301Çóµ÷¼Á
ÒѾÓÐ4È˻ظ´
0703»¯Ñ§336·ÖÇóµ÷¼Á
ÒѾÓÐ5È˻ظ´
301Çóµ÷¼Á
ÒѾÓÐ4È˻ظ´
²ÄÁÏר˶306Ó¢Ò»Êý¶þ
ÒѾÓÐ9È˻ظ´
304Çóµ÷¼Á
ÒѾÓÐ8È˻ظ´
²ÄÁϹ¤³Ìר˶µ÷¼Á
ÒѾÓÐ5È˻ظ´
344Çóµ÷¼Á
ÒѾÓÐ4È˻ظ´
» ÇÀ½ð±ÒÀ²£¡»ØÌû¾Í¿ÉÒԵõ½:
ɽ¶«Õ÷Å®ÓÑ£¬×ø±ê¼ÃÄÏ
+1/168
É¢½ð±Ò£¬ÇóºÃÔË£¬×£ÃæÉÏ˳Àû£¡
+2/160
ÎÂÖÝ´óѧÂÀ¾§¾§¿ÎÌâ×é2026ÄêÕÐÉú
+1/90
רҵ¼¼Êõ¿ª·¢¼°µÚÈý·½¼ì²â
+1/87
¹âѧ¹¤³Ìѧ˶µ÷¼ÁÐÅÏ¢
+2/56
´ß»¯·½ÏòÍÆ¼öÒ»¸ö¼«ºÃµÄ²©µ¼
+1/39
1
+1/37
¹ØÓÚ̼Á¿×ӵ㿹¾úµÄÑо¿
+1/35
ÖпÆÔºÉú̬»·¾³Ñо¿ÖÐÐĹúÖØÊµÑéÊÒÕÐÆ¸¿Í×ùÑо¿Éú1-2Ãû
+1/31
ÖØÇìÎÄÀíѧԺ»¯Ñ§Óë»·¾³¹¤³ÌѧԺ 2026 ½ì˶ʿÑо¿Éúµ÷¼Á֪ͨ
+1/18
ÄÏ¿ª´óѧÂÞ¾°É½½ÌÊÚ¿ÎÌâ×éÕÐÊÕ2026ÄêÈëѧ²©Ê¿Éú£¨¹â/µç´ß»¯·½Ïò£©
+2/14
ÄϾ©ÁÖÒµ´óѧ»¯Ñ§¹¤³ÌѧԺ°ØÐÊ·å¿ÎÌâ×éÕÐÊÕ2026ÄêÉêÇ뿼ºËÖÆ²©Ê¿2Ãû
+1/11
ÉϺ£¿Æ¼¼´óѧÕÐÊÕÓлú»¯Ñ§·½ÏòÕÐÊÕ2026¼¶¹¤³Ì²©Ê¿
+1/7
26Ä격ʿÕÐÉú
+1/6
¿ÎÌâ×éÕÐÊÕ»·¾³¼°Ïà¹Ø×¨Òµµ÷¼Á˶ʿÑо¿Éú£¨»¶ÓÓÅÐãѧÉú¼ÓÈ룩
+1/6
ÉϺ£½»Í¨´óѧ»¯Ñ§»¯¹¤Ñ§ÔºÕÅÖÇÌοÎÌâ×é³ÏƸ²©Ê¿ºó
+1/6
·¢paper
+1/5
2026¿¼ÑеÄͬѧ£¬·ÖÊý²»¹»£¿Ïëµ÷¼ÁÉϰ¶µÄͬѧ£¬À´¿´
+1/5
¼ÓÄô󰢶û²®Ëþ´óѧÕÐÊÕµç´Å¡¢ÎÞÏßͨÐÅ¡¢»úÆ÷ѧϰ·½ÏòÈ«½±Ë¶Ê¿/²©Ê¿/²©Ê¿ºó/·ÃÎÊѧÕß
+2/2
339Çóµ÷¼Á
+1/1
kaobo2012
ľ³æ (ÕýʽдÊÖ)
- ·ÒëEPI: 3
- Ó¦Öú: 100 (³õÖÐÉú)
- ½ð±Ò: 5426.6
- Ìû×Ó: 731
- ÔÚÏß: 255.3Сʱ
- ³æºÅ: 1168995
|
The paper researches on voltage/current output of constant potential rectifier measuring by CIPS and changes of pipe-to-soil potential of buried pipeline with the ON/OFF cycle of current interrupter .meanwhile , systematically suggests that Off cycle is appropriate with cathodic protection system and the influence of On cycle to ON/OFF potential . Ï£Íû¶ÔÂ¥Ö÷ÓаïÖú£¡ |
2Â¥2011-02-21 23:23:27
8814402
ÖÁ×ðľ³æ (Ö°Òµ×÷¼Ò)
- ·ÒëEPI: 509
- Ó¦Öú: 18 (СѧÉú)
- ¹ó±ö: 0.381
- ½ð±Ò: 12916.1
- Ìû×Ó: 4183
- ÔÚÏß: 357.8Сʱ
- ³æºÅ: 1184404
imrxuchengwei(½ð±Ò+6, ·ÒëEPI+1): ¸ÐлÄúµÄ°ïÖú 2011-02-22 08:32:22
|
In this paper, we studied variation of voltage / current output and variation of the buried pipeline pipe-to-soil potential with on-off cycle of the current interrupter during the interval potential method (CIPS) measurement process were and thereby systematically described reasonable design of off cycle under the existing cathodic protection system and the impact of on cycle to pipe-to-soil on/off potential. |
3Â¥2011-02-22 08:22:49













»Ø¸´´ËÂ¥