求miRNA表达水平检测具体方法
|
|||
| 有一种荧光定量PCR检测的方法,是利用茎环引物做的,想知道具体方法,论文形式最好,越具体越好 |
» 猜你喜欢
职称评审没过,求安慰
已经有20人回复
投稿Elsevier的Neoplasia杂志,到最后选publishing options时页面空白,不能完成投稿
已经有20人回复
垃圾破二本职称评审标准
已经有12人回复
EST投稿状态问题
已经有7人回复
谈谈两天一夜的“延安行”
已经有15人回复
毕业后当辅导员了,天天各种学生超烦
已经有4人回复
聘U V热熔胶研究人员
已经有10人回复
求助文献
已经有3人回复
投稿返修后收到这样的回复,还有希望吗
已经有8人回复
三无产品还有机会吗
已经有6人回复
bomuwang
木虫 (正式写手)
- 应助: 0 (幼儿园)
- 金币: 1833.1
- 红花: 2
- 帖子: 466
- 在线: 151.1小时
- 虫号: 584136
- 注册: 2008-08-01
- 专业: 无机合成和制备化学
2楼2009-12-25 19:32:37
3楼2009-12-25 21:32:43
telomerase
至尊木虫 (著名写手)
cain
- 应助: 18 (小学生)
- 贵宾: 1.893
- 金币: 11090
- 红花: 22
- 帖子: 1971
- 在线: 261.3小时
- 虫号: 345402
- 注册: 2007-04-14
- 专业: 临床生物化学检验

4楼2009-12-26 03:49:57
telomerase
至尊木虫 (著名写手)
cain
- 应助: 18 (小学生)
- 贵宾: 1.893
- 金币: 11090
- 红花: 22
- 帖子: 1971
- 在线: 261.3小时
- 虫号: 345402
- 注册: 2007-04-14
- 专业: 临床生物化学检验
★ ★ ★
chuang1381(金币+3,VIP+0): 1-5 17:52
chuang1381(金币+3,VIP+0): 1-5 17:52
|
Real-time RT-PCR for miRNA detection 187-plex RT-PCR was adapted for the rat sequences from Lao et al. (2006) based on Sanger’s October 2005 registry. Briefly, multiplex reverse transcription primers were generated with a common 20-nt stem–loop followed by 8 nt complementary to the 39-end of a given miRNA (e.g., 59-AACTATAC-39 for rnolet- 7a). Reverse transcriptase reactions were performed in 5 mL containing 13 cDNA Archiving Kit buffer (Applied Biosystems), 10 units of MMLV reverse transcriptase, 1.25 mM each dNTP, 1.3 units of RNase inhibitors (Applied Biosystems), 2.5 nM each reverse primer, and 2 mL of laser capture microdissection samples. Reactions were 30 cycles for 30 sec at 20°C, 30 sec at 42°C, and 1 sec at 50°C and one cycle for 5 min at 85°C to inactivate the enzyme. Pre-PCR cDNA was pre-amplified using a common reverse primer (UR) to the 20-nt stem–loop and multiplexed z18-nt forward primers (FPs) with a common 59-end and a 39-end matching 12–17 nt of the 59-end of a given miRNA (e.g., 59-TCCAGCTCCTATATGAT- 39 for rno-let-7a). The amplification was performed in 25 mL containing 13 Universal Master Mix with no UNG (Applied Biosystems), 50 nM each FP, 5 mM UR, 6.25 units of AmpliTaq Gold polymerase (Applied Biosystems), 0.5 mM each dNTP, 2 mM MgCl2, and 5 mL of the initial reverse transcriptase amplification. Reactions were one cycle of 10 min at 95°C, 2 min at 55°C, and 14 cycles of 1 sec at 95°C and 1 min at 65°C. Real-time PCR The product of this amplification was diluted four times, and 0.1 mL was used for real-time PCR performed in 10 mL containing 13 Universal Master Mix with no UNG (Applied Biosystems), 0.25 mM FP, 0.1 mM TaqMan probe, and 5 mM UR. The miRNA specificity for each reaction was provided by the miRNA-specific sequences of the FP and TaqMan probes. Real-time PCR was performed in a Biosystems 7500HT 96-well plate Sequence Detection System using 40 cycles of 15 sec at 95°C and 1 min at 60°C. All reactions were run in duplicate. The threshold cycle (Ct) was determined as the fractional cycle number at which the fluorescence passes the fixed threshold. For primer sequences, see Supplemental Table 2. All Ct values were averaged over two to four repeated biological experiments each with two averaged realtime PCR experimental replicates. Single-plex real-time PCR Single-plex real-time PCR was performed as described for multiplex real-time PCR with one modification: A single miRNAspecific primer was used instead of multiple primers. Real-time PCR for mRNA detection RT-PCR was performed to measure the amount of mRNAs in the same laser capture microdissected samples. Reverse transcriptase reactions were performed in 5 mL containing 13 cDNA Archiving Kit buffer (Applied Biosystems), 10 units MMLV reverse transcriptase, 1.25 mM each dNTP, 1 unit of RNase inhibitor (Applied Biosystems), 2 mM random primer, and 1 mL of laser capture microdissection samples. Reactions were 10 min at 20°C, 120 min at 37°C, and 5 min at 85°C to inactivate the enzyme. cDNA was pre-amplified using gene-specific forward primers and reverse primers. The amplification was performed in 25 mL containing 13 Universal Master Mix with no UNG (Applied Biosystems), 50 nM each FP, 50 nM each RP, 6.25 units of AmpliTaq Gold polymerase (Applied Biosystems), 0.5 mM each dNTP, 0.75 mM MgCl2, and 5 mL of the initial reverse transcriptase amplification. Reactions were one cycle for 10 min at 95°C, 2 min at 55°C, and 14 cycles of 1 sec at 95°C and 1 min at 65°C. The product of this amplification was diluted four times, and 0.1 mL was used for realtime PCR reactions detecting mRNAs. It was performed in 10 mL coBiosystems), 500 nM FP, 200 nM TaqMan probe, and 500 nM UR. Real-time PCR was performed as above. For primer sequences, see Supplemental Table 1.ntaining 13 Universal Master Mix with no UNG (Applied |