| ²é¿´: 583 | »Ø¸´: 5 | |||
| µ±Ç°Ö÷ÌâÒѾ´æµµ¡£ | |||
| µ±Ç°Ö»ÏÔʾÂú×ãÖ¸¶¨Ìõ¼þµÄ»ØÌû£¬µã»÷ÕâÀï²é¿´±¾»°ÌâµÄËùÓлØÌû | |||
hnxqbľ³æ (СÓÐÃûÆø)
|
[½»Á÷]
¡¾ÇóÖú¡¿ÄÄλ¸ßÈËÄܸæËßÎÒÕâÊÇ̨ʲô¹âѧÒÇÆ÷
|
||
|
±¾ÈË»·¾³×¨Òµ£¬ÔÚ×ö²»Í¬ÖÖÀಣÁ§¹âѧ·ÖÑ¡ÎÄÏ×Ñо¿Ê±£¬Óöµ½Ò»ÖÖÒÇÆ÷£¬Ò»Ö±Ã»ÅªÇå³þÕâÊÇ̨ʲô¹âѧÒÇÆ÷£¬ÄÄÀïÓÐÂô£¿»òÔÚÄÄÀïʵÑéÊÒÓÐÕâÖÖÒÇÆ÷£¿¼±ÇóѧÎïÀí¹âѧµÄÏȱ²¸øÓèÖ¸µ¼½â´ð¡£ÎÒ½«ÎÄÏ×ÖÐÉæ¼°µÄÄÚÈÝÌùÔÚÏÂÃæ£º Ceramic glass and glass samples spectra, in the mid-infrared field, were detected using a Perkin SPECTRUM-ONE Fourier transform-infrared (FT-IR) spectrometer, capable of data collection over a range of 370¨C7800 cm¨C1. The instrument can be configured to run in single-beam, ratio, or interferogram modes. The best resolution was 0.5 cm¨C1. A mid-range deuterated triglycine sulphate infrared detector processed the signals with a 68340 integrated chip. The sample compart- ment was purgeable. The instrument was interfaced to Perkin Elmer SPECTRUM-ONE software.The FT-IR spectrometer recorded the interaction of IR radiation with a sample, measuring the frequencies at which the sample absorbed the radiation and the intensities of the absorption. ![]() |
» ²ÂÄãϲ»¶
332Çóµ÷¼Á
ÒѾÓÐ7È˻ظ´
348Çóµ÷¼Á
ÒѾÓÐ4È˻ظ´
305Çóµ÷¼Á
ÒѾÓÐ8È˻ظ´
Ò»Ö¾Ô¸±±¾©»¯¹¤´óѧ²ÄÁÏÓ뻯¹¤£¨085600£©296Çóµ÷¼Á
ÒѾÓÐ13È˻ظ´
µ÷¼Á310
ÒѾÓÐ9È˻ظ´
±¾¿ÆË«·Ç²ÄÁÏ£¬¿ç¿¼Ò»Ö¾Ô¸»ªµç085801µçÆø£¬283Çóµ÷¼Á£¬ÈκÎרҵ¶¼¿ÉÒÔ
ÒѾÓÐ8È˻ظ´
µ÷¼ÁÇóԺУÕÐÊÕ
ÒѾÓÐ6È˻ظ´
085600 ²ÄÁÏÓ뻯¹¤ 329·ÖÇóµ÷¼Á
ÒѾÓÐ11È˻ظ´
ÇóÊÕÁô
ÒѾÓÐ3È˻ظ´
0856Çóµ÷¼Á
ÒѾÓÐ14È˻ظ´
hnxqb
ľ³æ (СÓÐÃûÆø)
- Ó¦Öú: 0 (Ó×¶ùÔ°)
- ½ð±Ò: 1644.6
- É¢½ð: 36
- Ìû×Ó: 173
- ÔÚÏß: 169.2Сʱ
- ³æºÅ: 439831
- ×¢²á: 2007-10-23
- רҵ: »·¾³¿ÆÑ§
|
Ê×ÏÈллÄãµÄ»Ø´ð£¬µ«²»ÊÇÆøÏàÉ«Æ×ÒÇ£¬ ´ÓͼƬÉÏ¿´£¬ºÃÏñÀàËÆÓÚÕÕÏà»ú¾µÍ·ÑùµÄ¶«Î÷£¬²¢ÇÒÓÐÓ¢ÎĽéÉÜÈçÏ£º The ImSpector™ is an imaging spectrograph that captures a line image and disperses it to spectrum in a direction orthogonal to the line image. It is ideally suited for line inspection and color inspection machine vision systems. When coupled to a conventional black-and- white CCD camera, the addition of the ImSpector™ forms a spectral line imaging system. Based on a unique prism-grating-prism (PGP) optical design, the ImSpector™ is the only ommercially available, direct-line- of-sight imaging spectrograph in which light goes through a straight optical axis. Unlike reflective techniques, the spectral dispersion is polarization independent. The spectrograph conveniently fits directly to most conventional C-mount imaging cameras or it can be coupled directly to PixelVision¡¯s highperformance back-illuminated cameras directly between the lens and the camera without reconfiguring the optomechanical setup. The ImSpector™ has a broad spectral range from the 400 nm range up through the NIR (greater than 1.7 (m) and has a spectral resolution of between 5 nm and 10 nm. ˳±ã˵һÏ£¬ÎÒÊÇÓÃÕâÖÖÒÇÆ÷²âÊÔ²£Á§Ë鯬¶ÔºìÍâ¹âÎü¹âÇ¿¶ÈÓõģ¬ÇëÎÊÕâÊÇʲô¹âѧ½ÓÊÕÆ÷ÄØ£¿ |
3Â¥2009-12-07 12:04:36
zxyan
ÖÁ×ðľ³æ (ÎÄ̳¾«Ó¢)
- Ó¦Öú: 56 (³õÖÐÉú)
- ½ð±Ò: 21128.1
- É¢½ð: 2151
- ºì»¨: 6
- ɳ·¢: 2
- Ìû×Ó: 18284
- ÔÚÏß: 881.4Сʱ
- ³æºÅ: 818017
- ×¢²á: 2009-07-29
- רҵ: ȼÉÕѧ
¡ï ¡ï ¡ï
Сľ³æ(½ð±Ò+0.5):¸ø¸öºì°ü£¬Ð»Ð»»ØÌû½»Á÷
Сľ³æ:)(½ð±Ò+2,VIP+0):3q 12-7 21:00
Сľ³æ(½ð±Ò+0.5):¸ø¸öºì°ü£¬Ð»Ð»»ØÌû½»Á÷
Сľ³æ:)(½ð±Ò+2,VIP+0):3q 12-7 21:00
ÊÇÆøÏàÉ«Æ×ÒǺ͸¶Á¢Ò¶ºìÍâ±ä»»Æ×ÒÇ |
2Â¥2009-12-07 10:33:23
fengaas
гæ (³õÈëÎÄ̳)
- Ó¦Öú: 1 (Ó×¶ùÔ°)
- ½ð±Ò: 1.1
- Ìû×Ó: 6
- ÔÚÏß: 3.6Сʱ
- ³æºÅ: 238280
- ×¢²á: 2006-04-05
- רҵ: Äý¾Û̬ÎïÐÔ II £ºµç×ӽṹ
Ó¦¸ÃÊÇÕâ¸ö¶«Î÷°É
¡ï ¡ï ¡ï ¡ï ¡ï ¡ï
Сľ³æ(½ð±Ò+0.5):¸ø¸öºì°ü£¬Ð»Ð»»ØÌû½»Á÷
Сľ³æ:)(½ð±Ò+5,VIP+0):3q 12-7 21:00
Сľ³æ(½ð±Ò+0.5):¸ø¸öºì°ü£¬Ð»Ð»»ØÌû½»Á÷
Сľ³æ:)(½ð±Ò+5,VIP+0):3q 12-7 21:00
|
http://www.gclctoronto.com/spectrumone.htm ¸µÁ¢Ò¶±ä»»ºìÍâ¹âÆ×ÒÇ |
4Â¥2009-12-07 12:51:55
hnxqb
ľ³æ (СÓÐÃûÆø)
- Ó¦Öú: 0 (Ó×¶ùÔ°)
- ½ð±Ò: 1644.6
- É¢½ð: 36
- Ìû×Ó: 173
- ÔÚÏß: 169.2Сʱ
- ³æºÅ: 439831
- ×¢²á: 2007-10-23
- רҵ: »·¾³¿ÆÑ§
5Â¥2009-12-07 19:56:20















»Ø¸´´ËÂ¥