lrsfbp

银虫 (小有名气)

[交流] 【讨论】大家帮我看看这个审稿意见

Cyclic voltammograms have been registered at potential scan rate about  20 mV/s, which corresponds to time of an anode or cathodic half-cycle of 1.5 minutes. It is known that lithium insertion-extraction process is limited by lithium diffusion in solid state. At such high potential scan rate electrochemical process will be occur mainly on the electrode surfaces but not in electrode bulk. It leads to decrease of insertion capacity. As a rule, potential scan rate for study of such materials should be from 0.02 to 0.1 mV/s.
我电化学方面的东西不是很熟。所以一直没有明白这是什么意思。但是我看了已发表文章的相关数据,他们在做循环伏安时一般也都是20mv/s的。请大家帮忙给点意见。同时将我所做的在20mv/s和0.1mv/s的循环伏安图附上。另外,扫描速度非常小的时候,输出电流很小,这样它的容量能提高么?请大家多多指教