| ²é¿´: 1770 | »Ø¸´: 5 | |||
| ¡¾ÐüÉͽð±Ò¡¿»Ø´ð±¾ÌûÎÊÌ⣬×÷ÕßYummyym½«ÔùËÍÄú 30 ¸ö½ð±Ò | |||
Yummyymгæ (ÕýʽдÊÖ)
|
[ÇóÖú]
Éó¸åÈËÎÊÌâºÃÄѰ¡ ÒÑÓÐ4È˲ÎÓë
|
||
AQY is reported and SCC, but the procedures lack key metrological details: bandpass (FWHM), spectral irradiance at the reactor, photon flux calibration (e.g., ferrioxalate actinometry), optical geometry (path length, reactor albedo), and inner-filter effects in turbid slurries. Please provide calibrated photon flux at each wavelength at the sample plane, scattering correction, and the method for absorbed-photon-to-chemical efficiency (APCE). The SCC input power uses 0.314 W from 1000 W¡¤m-2¡Á3.14¡Á10-4 m2 (a 1-cm-diameter spot) for a 120 mL slurry with 200 mg catalyst¡ªthis geometry likely underestimates incident power on the illuminated volume or overestimates absorption. Please show the illuminated area, light footprint mapping on the reactor, and sensitivity of SCC to stirrer speed/optical depth. ÓÐÄÄλ´óÉñÄܰïÎÒ½âÊÍÒ»ÏÂÉó¸åÈËÎʵĵ½µ×ÊÇɶ²»£¿¶¼²»ÖªµÀÕ¦»Ø¸´ |
» ²ÂÄãϲ»¶
297Çóµ÷¼Á
ÒѾÓÐ12È˻ظ´
26µ÷¼Á 086003
ÒѾÓÐ3È˻ظ´
265Çóµ÷¼Á
ÒѾÓÐ20È˻ظ´
271·ÖÇóµ÷¼ÁѧУ
ÒѾÓÐ11È˻ظ´
320·ÖÈ˹¤ÖÇÄܵ÷¼Á
ÒѾÓÐ6È˻ظ´
Çóµ÷¼Á£¬Ò»Ö¾Ô¸ÄϾ©º½¿Õº½Ìì´óѧ £¬080500²ÄÁÏ¿ÆÑ§Ó빤³Ìѧ˶
ÒѾÓÐ8È˻ظ´
280Çóµ÷¼Á
ÒѾÓÐ19È˻ظ´
Çó²ÄÁϵ÷¼Á£¬Ò»Ö¾Ô¸Ö£ÖÝ´óѧ289·Ö
ÒѾÓÐ15È˻ظ´
26¿¼Ñе÷¼Á0710 0860
ÒѾÓÐ6È˻ظ´
282Çóµ÷¼Á
ÒѾÓÐ22È˻ظ´
nono2009
³¬¼¶°æÖ÷ (ÎÄѧ̩¶·)
No gains, no pains.
-

ר¼Ò¾Ñé: +21105 - SEPI: 10
- Ó¦Öú: 28684 (Ժʿ)
- ¹ó±ö: 513.911
- ½ð±Ò: 2555230
- É¢½ð: 27828
- ºì»¨: 2148
- ɳ·¢: 66666
- Ìû×Ó: 1602255
- ÔÚÏß: 65200.9Сʱ
- ³æºÅ: 827383
- ×¢²á: 2009-08-13
- ÐÔ±ð: GG
- רҵ: ¹¤³ÌÈÈÎïÀíÓëÄÜÔ´ÀûÓÃ
- ¹ÜϽ: ¿ÆÑмҳﱸίԱ»á
2Â¥2025-10-12 08:55:29
±±¾©À³ÒðÈóÉ«
½ð³æ (ÖøÃûдÊÖ)
- Ó¦Öú: 454 (˶ʿ)
- ½ð±Ò: 119.5
- É¢½ð: 77
- Ìû×Ó: 1267
- ÔÚÏß: 131.8Сʱ
- ³æºÅ: 26529150
- ×¢²á: 2021-06-04
- רҵ: µç»¯Ñ§
3Â¥2025-10-13 09:05:43
ca0yan9
¾èÖú¹ó±ö (ÎÄ̳¾«Ó¢)
Сľ³æÓ×¶ùÔ°ÈÙÓþÔ°³¤
- Ó¦Öú: 79 (³õÖÐÉú)
- ½ð±Ò: 310342
- É¢½ð: 3400
- ºì»¨: 451
- Ìû×Ó: 29293
- ÔÚÏß: 2702.1Сʱ
- ³æºÅ: 1561798
- ×¢²á: 2012-01-03
- ÐÔ±ð: GG
- רҵ: ÎÞ»ú²ÄÁÏ»¯Ñ§
¡¾´ð°¸¡¿Ó¦Öú»ØÌû
|
Please provide calibrated photon flux at each wavelength at the sample plane, scattering correction, and the method for absorbed-photon-to-chemical efficiency (APCE) Ö÷ÒªÊÇÐèÒª¶Ô¹âµÄÇ¿¶È£¬²¨³¤½øÐÐÏêϸ˵Ã÷£ºÐèÒª²â¶¨²»Í¬²¨³¤µÄ¹âÇ¿¶È£¬¶øÇÒ¹âÇ¿¶ÈÐèÒª¶ÔÓ¦ÓÚÑùÆ·ËùÔÚλÖ㬶øÇÒÐèÒª¸ø³öAPCEЧÂʵļÆËã·½·¨ Please show the illuminated area, light footprint mapping on the reactor, and sensitivity of SCC to stirrer speed/optical depth. Õâ¸öÊÇÐèÒª¸ø³öÑùÆ·±»¹âÕÕÉäµÄÃæ»ý£¬¹âÕÕÉäµÄ·Ö²¼Í¼£¬²¢ÇÒÐèÒª¸ø³ö¹â´ß»¯ÊÇ·ñÓ벻ͬ½Á°èËÙ¶È¡¢²»Í¬¹âÕÕÉî¶ÈÓÐ¹Ø |
4Â¥2025-12-10 07:32:40
babero
ÖÁ×ðľ³æ (ÎÄ̳¾«Ó¢)
- Ó¦Öú: 669 (²©Ê¿)
- ½ð±Ò: 39455.8
- É¢½ð: 59
- ºì»¨: 41
- Ìû×Ó: 14347
- ÔÚÏß: 2086.7Сʱ
- ³æºÅ: 458624
- ×¢²á: 2007-11-13
- רҵ: ×ÔÈ»µØÀíѧ
5Â¥2025-12-11 17:59:48
6Â¥2026-03-28 10:51:41














»Ø¸´´ËÂ¥