| 查看: 887 | 回复: 7 | |||
| 当前主题已经存档。 | |||
limin800111金虫 (小有名气)
|
[交流]
【求助】Autolab电化学工作站能做脉冲电沉积金属吗?
|
||
|
请教大家,Autolab电化学工作站能做脉冲电沉积金属吗? 非常感谢! |
» 猜你喜欢
1
已经有21人回复
储能与电子材料课题组 招收硕士 or 博士研究生——以色列理工-GTIIT联培
已经有19人回复
分析化学论文润色/翻译怎么收费?
已经有104人回复
意大利卡梅里诺大学 Marco Giorgetti 教授课题组招收同步辐射方向CSC博士生、博士后
已经有15人回复
江西师范大学化学与材料学院能源光催化团队招博士1名,欢迎联系报名
已经有0人回复
书籍和论文
已经有1人回复
弗吉尼亚理工大学李腾飞课题组招聘电催化博后和博士生
已经有0人回复
锆合金吸氢材料
已经有0人回复
求助电化学测试原理,电化学测试技术分析等PPT
已经有0人回复
limin800111
金虫 (小有名气)
- 应助: 0 (幼儿园)
- 金币: 1559.4
- 帖子: 189
- 在线: 127.9小时
- 虫号: 216637
- 注册: 2006-03-11
- 性别: MM
- 专业: 金属功能材料
2楼2009-10-29 17:41:29

3楼2009-10-29 19:19:28
limin800111
金虫 (小有名气)
- 应助: 0 (幼儿园)
- 金币: 1559.4
- 帖子: 189
- 在线: 127.9小时
- 虫号: 216637
- 注册: 2006-03-11
- 性别: MM
- 专业: 金属功能材料
4楼2009-10-29 20:22:09
limin800111
金虫 (小有名气)
- 应助: 0 (幼儿园)
- 金币: 1559.4
- 帖子: 189
- 在线: 127.9小时
- 虫号: 216637
- 注册: 2006-03-11
- 性别: MM
- 专业: 金属功能材料
5楼2009-10-29 20:38:19

6楼2009-10-29 21:19:55
★
小木虫(金币+0.5):给个红包,谢谢回帖交流
小木虫(金币+0.5):给个红包,谢谢回帖交流
|
Voltammetric analysis 2.3 Normal pulse voltammetry 2.3 Normal pulse voltammetry Fig. 2 Normal pulse voltammetry While applying sampled dc, the reactions are allowed to proceed during the whole interval time. As a result, the region near the electrode is depleted from reactant, lowering the faradaic current. Furthermore, reaction product can accumulate on the electrode, poisoning its surface. To decrease these detrimental effects, the normal pulse technique was developed. Here, the electrode is kept at an inactive potential for most of the interval time: the base potential. Just prior to the measurement, the electrolysis potential is applied: the normal pulse. Concerning the duration of the pulse period, the familiar discussion applies here: a shorter pulse will yield response with a higher magnitude but the ratio of (unwanted) capacitive current will be higher as well. This technique is approximately a factor 10 more sensitive than sampled dc. However, the data analysis is more complicated. Furthermore, since the time scale employed is shorter, it is possible to experience effects due to irreversibility of the electrode reaction. Then again, that might be just the objective. The parameters for this method are chosen similarly to sampled dc, with the addition of a pulse time. Normally, a reasonable value for the pulse time would be about 50ms. Internally, the software will try to adopt a sampling period that complies the line period. When the pulse period is larger than 40ms, it will collect samples and average them during the last 20ms (for 50Hz line frequency). |

7楼2009-10-29 21:39:29
limin800111
金虫 (小有名气)
- 应助: 0 (幼儿园)
- 金币: 1559.4
- 帖子: 189
- 在线: 127.9小时
- 虫号: 216637
- 注册: 2006-03-11
- 性别: MM
- 专业: 金属功能材料
8楼2009-10-30 08:50:10











回复此楼