[交流] 【求助】PCM计算出错,大家帮忙看看怎么解决?

PCM计算出错,大家帮忙看看怎么解决?谢谢!

WARNING!  Serious error in surface integrals.
Nuclear flux =    151.63 Qnuc =   154.00 Error in int =     0.00
It is probable that some of the solute is outside the cavity and/or
parts of the cavity surface cannot be reached from the origin.
Try more integration points or a different set of integration origins.

Surface Problems in SciFoc
Error termination via Lnk1e in /home/yebing/g03/l502.exe at Thu Jul 23 11:07:41 2009.
Job cpu time:  0 days  0 hours  3 minutes 35.2 seconds.
File lengths (MBytes):  RWF=     47 Int=      0 D2E=      0 Chk=      1 Scr=      1
回复此楼
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖

zhangdi6802

银虫 (小有名气)

★ ★
小木虫(金币+0.5):给个红包,谢谢回帖交流
lei0736(金币+1,VIP+0):谢谢 7-27 10:04
这个问题我也遇到过,可能是分子量太大了,你是选用的SCI-PCM吧,试试IPCM
亮剑精神
2楼2009-07-23 20:23:08
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖

zeozhou

木虫 (小有名气)

★ ★ ★
lei0736(金币+3,VIP+0):谢谢 7-27 10:04
是在构建溶剂模型的时候,空穴表面的问题。
可以使用不同的球半径来构建溶剂空穴
试试这个
radii=uaks