5个reviewer,其中一个和AE比较犀利。小白心态有点崩,请问大家遇到这种情况是怎么处理的。


Reviewer: 1

Comments to the Author
1- The language of the manuscript must be improved.
There are many loose sentences, which are both structurally and grammatically incorrect. Also, There are several typesetting and grammatical mistakes in the manuscript, and the write up is not good.
2- Why you discuss about current source inverters?? These inverters? are rarely used in grid-connected systems.
3- In relation to the previous comment, all reviewed papers are about the voltage source inverters.
4- Equation (33) is lost.
5- All figures have low quality and can not be used.
6- Why the grid impedance is ignored? In weak grid condition, it may affect the system stability.
7- The sampling frequency range in table 1 must be checked.
8- Why the effect of the integral term in the PR controller is ignored on the system stability?


Reviewer: 2

Comments to the Author
This paper’s examination of different delay’s impacts on the stability of grid-tied CSI is valuable.? Many of the analytical analysis are sound, and the experiment results have been presented to exam the stability of the system. (格式问题比较多,我删了一些)
However, I have following comments and recommendations:
.
5. Pg. 3, Line 23-41:? the description here is not clear.? You are discussing some theory from stability analysis.? Please make sure you cite appropriate references here.? In addition, please provide description for all the undefined variables like L(w), phi(w).

6. Pg. 3, Eq. (7): why when w=wres, it is positive infinity?? There is still jCrw in the denominator.

7. Fig. 5:? I recommend you add word description in Fig. 5 to show the two bode diagram lines that are stable.


15. Fig. 7: please add arrows in the figure to show the root loci with respect to the variation of lambda.

16. Pg. 7, Line 26: “a method for suppressing…” is confusing.? I think you have not proposed any new method in this paper; instead, you are designing controller in the stable region you evaluated.

17. Grammar issues:? there are multiple grammar issues throughout the paper.? Please carefully read through the paper and correct the errors.?



Reviewer: 3

Comments to the Author
1. Please correct double-check the paper for typos such as “controlof” and “controlis”.
2. For grid-connected inverters, LC and LCL filters are more popular. Are the results presented in the paper sill applicable to these types of filters?
3. As its name suggests, grid-connected inverters are often tied to a grid whose impedance might vary significantly depending on operation conditions. How could a weak grid be considered in the analysis?
4. The current controller is simplified as a proportional gain. Could the author justify such as simplification?
5. It is suggested to point out the application of the paper. Generally, the switching frequency, delay, and resonant frequency are chosen considering the specifications of the system hardware and grid interconnection requirements.

Reviewer: 4

Comments to the Author
This review has some remarks as follows:
- in Section III (A) is repeated paragraph ?The control block … the following formula (11)”,
- in Section II (B) is incorrect reference to the Fig. 3.,
- in Section III (A) equation nr 33 is not numbered,
- there is a few symbols in the paper with wrong format (without italics),
- the author(s) should present additional figure with a real photo of the test bench,
- the Figures 3, 5, 8, 9- 14 should be presented more clearly (larger fonts mainly),
- there is a missing Fig. 7 reference (?As shown in Fig. (a) and (c)…”),
- the author(s) refer(s) to the works, where general ranges of time delay for stability are provided for specific regulator parameters. Please present the new contribution more clearly. How the author(s) choose or calculate kp, or it is negligible in presented method? The author(s) should present: used parameters of regulator, and additional experimental result for different kp values if it has significant influence,
- some sentences should be better worded, please improve your written English.


Reviewer: 5

Comments to the Author
The presentation of the work and the method of tackling the problem are both similar to those of [35]. The authors must acknowledge this explicitly if they are not prepared to make significant changes.
1. The first and second paragraphs of Section III-A are same.
2. Where is the study of ‘the influence of the equivalent resistance’ as stated in the text following (18)?
3. (33) is missing.
4. A photo of the hardware system needs to be presented.
5. Where is the work of ‘suppressing system resonance’ as stated in the last paragraph of Section IV?
6. The references should be updated, as most of them are published before 2015.
7. The written English should be improved

AE Comments:
Associate Editor
Comments to the Author:
This paper has many problems. Its contents are very similar to [35]. Especially, most of the equations are exactly same as in [35] which shows that the paper lacks novelty. In addition, the reviewers have raised many comments regarding many issues such as grammar mistakes, organization of paper, quality of figures, etc.
?

Reviewer: 1

Comments to the Author
1- The language of the manuscript must be improved.
There are many loose sentences, which are both structurally and grammatically incorrect. Also, There are several typesetting and grammatical mistakes in the manuscript, and the write up is not good.
2- Why you discuss about current source inverters?? These inverters? are rarely used in grid-connected systems.
3- In relation to the previous comment, all reviewed papers are about the voltage source inverters.
4- Equation (33) is lost.
5- All figures have low quality and can not be used.
6- Why the grid impedance is ignored? In weak grid condition, it may affect the system stability.
7- The sampling frequency range in table 1 must be checked.
8- Why the effect of the integral term in the PR controller is ignored on the system stability?


Reviewer: 2

Comments to the Author
This paper’s examination of different delay’s impacts on the stability of grid-tied CSI is valuable.? Many of the analytical analysis are sound, and the experiment results have been presented to exam the stability of the system. (格式问题比较多,我删了一些)
However, I have following comments and recommendations:
.
5. Pg. 3, Line 23-41:? the description here is not clear.? You are discussing some theory from stability analysis.? Please make sure you cite appropriate references here.? In addition, please provide description for all the undefined variables like L(w), phi(w).

6. Pg. 3, Eq. (7): why when w=wres, it is positive infinity?? There is still jCrw in the denominator.

7. Fig. 5:? I recommend you add word description in Fig. 5 to show the two bode diagram lines that are stable.


15. Fig. 7: please add arrows in the figure to show the root loci with respect to the variation of lambda.

16. Pg. 7, Line 26: “a method for suppressing…” is confusing.? I think you have not proposed any new method in this paper; instead, you are designing controller in the stable region you evaluated.

17. Grammar issues:? there are multiple grammar issues throughout the paper.? Please carefully read through the paper and correct the errors.?



Reviewer: 3

Comments to the Author
1. Please correct double-check the paper for typos such as “controlof” and “controlis”.
2. For grid-connected inverters, LC and LCL filters are more popular. Are the results presented in the paper sill applicable to these types of filters?
3. As its name suggests, grid-connected inverters are often tied to a grid whose impedance might vary significantly depending on operation conditions. How could a weak grid be considered in the analysis?
4. The current controller is simplified as a proportional gain. Could the author justify such as simplification?
5. It is suggested to point out the application of the paper. Generally, the switching frequency, delay, and resonant frequency are chosen considering the specifications of the system hardware and grid interconnection requirements.

Reviewer: 4

Comments to the Author
This review has some remarks as follows:
- in Section III (A) is repeated paragraph ?The control block … the following formula (11)”,
- in Section II (B) is incorrect reference to the Fig. 3.,
- in Section III (A) equation nr 33 is not numbered,
- there is a few symbols in the paper with wrong format (without italics),
- the author(s) should present additional figure with a real photo of the test bench,
- the Figures 3, 5, 8, 9- 14 should be presented more clearly (larger fonts mainly),
- there is a missing Fig. 7 reference (?As shown in Fig. (a) and (c)…”),
- the author(s) refer(s) to the works, where general ranges of time delay for stability are provided for specific regulator parameters. Please present the new contribution more clearly. How the author(s) choose or calculate kp, or it is negligible in presented method? The author(s) should present: used parameters of regulator, and additional experimental result for different kp values if it has significant influence,
- some sentences should be better worded, please improve your written English.


Reviewer: 5

Comments to the Author
The presentation of the work and the method of tackling the problem are both similar to those of [35]. The authors must acknowledge this explicitly if they are not prepared to make significant changes.
1. The first and second paragraphs of Section III-A are same.
2. Where is the study of ‘the influence of the equivalent resistance’ as stated in the text following (18)?
3. (33) is missing.
4. A photo of the hardware system needs to be presented.
5. Where is the work of ‘suppressing system resonance’ as stated in the last paragraph of Section IV?
6. The references should be updated, as most of them are published before 2015.
7. The written English should be improved

AE Comments:
Associate Editor
Comments to the Author:
This paper has many problems. Its contents are very similar to [35]. Especially, most of the equations are exactly same as in [35] which shows that the paper lacks novelty. In addition, the reviewers have raised many comments regarding many issues such as grammar mistakes, organization of paper, quality of figures, etc.

修改意见一共47条,我哭。对本人很重要的一篇文章,用了我所有的金币。
?

发自小木虫Android客户端
回复此楼

» 猜你喜欢

已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖

放马南山

新虫 (初入文坛)


小木虫: 金币+0.5, 给个红包,谢谢回帖
老哥,最后怎么样了?二审有结果了吗?
9楼2020-07-22 01:20:31
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖
查看全部 10 个回答

小木翔AI

新虫 (著名写手)

2楼2020-05-16 09:05:43
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖

通李曼谢

新虫 (著名写手)


小木虫: 金币+0.5, 给个红包,谢谢回帖
投稿之前尽量避免显而易见的小问题,你这真的有点恐怖。要是你不嫌麻烦的话,一条一条慢慢改。

发自小木虫Android客户端
3楼2020-05-16 09:11:29
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖

yekongdea

铜虫 (职业作家)


小木虫: 金币+0.5, 给个红包,谢谢回帖
必须一条一条好好修改,要不然很难中

发自小木虫Android客户端
4楼2020-05-16 09:21:03
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖
普通表情 高级回复 (可上传附件)
最具人气热帖推荐 [查看全部] 作者 回/看 最后发表
[考研] 中科大材料与化工319求调剂 +3 孟鑫材料 2026-03-14 3/150 2026-03-14 20:10 by ms629
[考研] 材料与化工 323 英一+数二+物化,一志愿:哈工大 本人本科双一流 +4 自由的_飞翔 2026-03-13 5/250 2026-03-14 19:39 by hmn_wj
[考研] 289求调剂 +4 这么名字咋样 2026-03-14 6/300 2026-03-14 18:58 by userper
[考研] 【0703化学调剂】-一志愿华中师范大学-六级475 +5 Becho359 2026-03-11 5/250 2026-03-14 11:35 by 哦哦123
[考研] 考研求调剂,工科,总分304 +5 矮子不想长高了 2026-03-08 8/400 2026-03-14 04:04 by JourneyLucky
[考研] 2026考研调剂+本科延边大学+山东大学+生物化学与分子生物学+有项目经验 +3 ccdsscjy 2026-03-10 3/150 2026-03-14 00:12 by JourneyLucky
[考研] 0805,333求调剂 +3 112253525 2026-03-10 3/150 2026-03-13 23:42 by JourneyLucky
[考研] 341求调剂 +3 番茄头--- 2026-03-10 3/150 2026-03-13 23:07 by JourneyLucky
[考研] 285 求调剂 资源与环境 一志愿北京化工大学 +3 未名考生 2026-03-10 3/150 2026-03-13 23:04 by JourneyLucky
[考研] 285求调剂 +6 柴郡猫_ 2026-03-12 6/300 2026-03-13 20:46 by hmn_wj
[考研] 材料与化工085600调剂求老师收留 +9 jiaanl 2026-03-11 9/450 2026-03-13 20:22 by JourneyLucky
[考研] 求b区学校调剂 +3 周56 2026-03-11 3/150 2026-03-13 16:20 by JourneyLucky
[考研] 302求调剂 +6 负心者当诛 2026-03-11 6/300 2026-03-13 16:11 by JourneyLucky
[考研] 328化工专硕求调剂 +4 。,。,。,。i 2026-03-12 4/200 2026-03-13 14:44 by JourneyLucky
[考研] 材料专硕274一志愿陕西师范大学求调剂 +4 薛云鹏 2026-03-13 4/200 2026-03-13 10:40 by 学员8dgXkO
[考研] 283求调剂,材料、化工皆可 +8 苏打水7777 2026-03-11 10/500 2026-03-13 09:06 by Linda Hu
[考研] 哈工大材料324求调剂 +6 闫旭东 2026-03-10 8/400 2026-03-10 22:49 by 星空星月
[考研] 调剂 +5 呵唔哦豁 2026-03-10 5/250 2026-03-10 22:00 by 28375m
[考研] 收调剂 +7 调剂的考研学生 2026-03-10 7/350 2026-03-10 17:57 by 麦茶汤圆
[考博] 求材料读博院校 +9 yanglei131 2026-03-08 9/450 2026-03-10 11:54 by 天道酬勤2026686
信息提示
请填处理意见