| ²é¿´: 1687 | »Ø¸´: 2 | ||
YEFU´óÈËгæ (СÓÐÃûÆø)
|
[ÇóÖú]
CFXÅúÁ¿¼ÆËã ÒÑÓÐ1È˲ÎÓë
|
|
ÇëÎÊÓдóÀпÉÒÔ½«CFX-Pre¼ÆËãµÄʱºò¸Ä³ÉÒÀ´Î¼ÆËãÿһ¸ö.defÎļþÂ𣿲»ÊÇÒ»´ÎÐÔÈÃËü¶¼ÔÚ¼ÆË㣬ÕâÑù¾Í¿ÉÒÔËãÍêÒ»¸öÏÈ¿´Ò»¸ö @wuming524 ·¢×ÔСľ³æIOS¿Í»§¶Ë |
» ²ÂÄãϲ»¶
332Çóµ÷¼Á
ÒѾÓÐ7È˻ظ´
348Çóµ÷¼Á
ÒѾÓÐ4È˻ظ´
305Çóµ÷¼Á
ÒѾÓÐ8È˻ظ´
Ò»Ö¾Ô¸±±¾©»¯¹¤´óѧ²ÄÁÏÓ뻯¹¤£¨085600£©296Çóµ÷¼Á
ÒѾÓÐ13È˻ظ´
µ÷¼Á310
ÒѾÓÐ9È˻ظ´
±¾¿ÆË«·Ç²ÄÁÏ£¬¿ç¿¼Ò»Ö¾Ô¸»ªµç085801µçÆø£¬283Çóµ÷¼Á£¬ÈκÎרҵ¶¼¿ÉÒÔ
ÒѾÓÐ8È˻ظ´
µ÷¼ÁÇóԺУÕÐÊÕ
ÒѾÓÐ6È˻ظ´
085600 ²ÄÁÏÓ뻯¹¤ 329·ÖÇóµ÷¼Á
ÒѾÓÐ11È˻ظ´
ÇóÊÕÁô
ÒѾÓÐ3È˻ظ´
0856Çóµ÷¼Á
ÒѾÓÐ14È˻ظ´
klzg77541812
ר¼Ò¹ËÎÊ (ÕýʽдÊÖ)
NVH-FEA¹¤³Ìʦ
- Ó¦Öú: 117 (¸ßÖÐÉú)
- ½ð±Ò: 2141.8
- ºì»¨: 28
- Ìû×Ó: 621
- ÔÚÏß: 606.2Сʱ
- ³æºÅ: 1479383
- ×¢²á: 2011-11-06
- ÐÔ±ð: GG
- רҵ: ¹ÌÌåÁ¦Ñ§
- ¹ÜϽ: ¼ÆËãÄ£ÄâÇø
¡¾´ð°¸¡¿Ó¦Öú»ØÌû
¸Ðл²ÎÓ룬ӦÖúÖ¸Êý +1
|
ÓÃcommandÈ¥¿ØÖưɣ¬·ÖΪ¶àÐУ¬ËãÍêÒ»¸ö£¬Äã¾Í¿ÉÒÔ¿´Ò»¸öÁË£¬¾ßÌåÃüÁîÈçÏ£¬×Ðϸ¿´¿´ Answer: The steps below assume that ANSYS CFX 19.2 is installed on a supported operating system and no firewalls are blocking communication across multiple computers is that is in use, CFX and HPC licenses are available. This Solution could be reused for other recent versions going back to 18.2 with changes to the v### in the path This also assumes you have working knowledge of Command Prompt on Windows OR terminal on Linux. If you are not comfortable with command lines, please request assistance from your Organization's IT administrator. Installation and Paths On Windows Default Installation path is C:\Program Files\ANSYS Inc\ and CFX solver is in C:\Program Files\ANSYS Inc\v192\CFX\bin\ You can try including this to the PATH or use the full path to cfx5solve On Linux if /ansys_inc softlink was created to the installation location then below is the path to cfx5solve /ansys_inc/v192/CFX/bin/ Test model and working directory Create a Working Directory preferable a path without spaces or special characters on Windows say C:\temp\cfxtest\test1 on Linux try /home/cfxtest Copy the example file below to the working directory in above Windows C: cd \temp\cfxtest\test1 copy "C:\Program Files\ANSYS Inc\v192\CFX\examples\StaticMixer.def" . Linux cd /home cp /ansys_inc/v192/CFX/examples/StaticMixer.def ./ Here are the steps to run CFX solver in different modes Serial Mode, uses 1 core On Windows "C:\Program Files\ANSYS Inc\v192\CFX\bin\cfx5solve.exe" -batch -serial -def StaticMixer.def On Linux /ansys_inc/v192/CFX/bin/cfx5solve -batch -serial -def StaticMixer.def Local machine only (Shared Memory Parallel) on one node change the command line flags to -batch -par -def StaticMixer.def -par-local -part 10 Local machine only (Distributed Memory Parallel) on one node change the command line flags to -batch -par -def StaticMixer1.def -par-dist "node01*2" NOTE: if you are on a headnode or loginhnode say hostname node00, then do not run the above from node00. ssh to node01 and run from there. The first node in the list should be the node you are running the command line from. To run across nodes on Linux On Linux passwordless ssh needs to be enabled. -batch -par -def StaticMixer1.def -par-dist "node01*2,node02*2" To force a particular start method from command line, this example shows Intel MPI distributed Parallel -batch -par -def StaticMixer1.def -par-dist "node01*2" -start-method "Intel MPI Distributed Parallel" For Debugging purposes add flag "-v" at the beginning without quotes To stop an existing solve say the first run, you can use the command. Be sure to run the command in the folder which contains the directory being referenced. Windows "C:\Program Files\ANSYS Inc\v19.x\CFX\bin\cfx5stop.exe" -directory StaticMixer_001.dir Linux /ansys_inc/v19.x/CFX/bin/cfx5stop -directory StaticMixer_001.dir |

2Â¥2019-07-17 09:38:31
YEFU´óÈË
гæ (СÓÐÃûÆø)
- Ó¦Öú: 0 (Ó×¶ùÔ°)
- ½ð±Ò: 97.8
- É¢½ð: 71
- Ìû×Ó: 107
- ÔÚÏß: 53.5Сʱ
- ³æºÅ: 7877436
- ×¢²á: 2018-02-03
- ÐÔ±ð: GG
- רҵ: ¹¤³ÌÈÈÎïÀíÏà¹Ø½»²æÁìÓò
3Â¥2019-07-18 09:02:37














»Ø¸´´ËÂ¥
YEFU´óÈË