【请教】测量IR 炉子的测温线(热电偶)J型K型的区别?
|
||
|
请问热电偶,J型与K型的有什么区别? 材质不同?还是形状不同? 貌似材质不同?测温有区别吗? 多谢! |
» 猜你喜欢
征友后感触
已经有10人回复
考博求助
已经有4人回复
憎水剂,表面活性剂
已经有3人回复
申博
已经有7人回复
食品与机械 编辑C处理稿子时间
已经有4人回复
注意啦!用基金购买打印纸、硒鼓、优盘、移动硬盘、个人计算机属于违规了
已经有4人回复
hui_jun_li
木虫 (正式写手)
- MM-EPI: 3
- 应助: 0 (幼儿园)
- 贵宾: 0.07
- 金币: 1576.2
- 红花: 6
- 帖子: 514
- 在线: 22.1小时
- 虫号: 748650
- 注册: 2009-04-14
- 性别: GG
- 专业: 金属材料, 电镜
★ ★
mselxp(金币+2,VIP+0):谢谢! 5-23 17:51
mselxp(金币+2,VIP+0):谢谢! 5-23 17:51
|
Type K (chromel–alumel) is the most common general purpose thermocouple. It is inexpensive and available in a wide variety of probes. They are available in the −200 °C to +1350 °C range. The type K was specified at a time when metallurgy was less advanced than it is today and, consequently, characteristics vary considerably between examples. Another potential problem arises in some situations since one of the constituent metals, nickel, is magnetic. One characteristic of thermocouples made with magnetic material is that they undergo a step change when the magnetic material reaches its Curie point. This occurs for this thermocouple at 354 °C. Sensitivity is approximately 41 µV/°C. Type J (iron–constantan) is less popular than type K due to its limited range (−40 to +750 °C). The Curie point of the iron (770 °C) causes an abrupt change to the characteristic and it is this that provides the upper temperature limit. Type J thermocouples have a sensitivity of about 50 µV/°C |