| ²é¿´: 12807 | »Ø¸´: 878 | |||
| µ±Ç°Ö»ÏÔʾÂú×ãÖ¸¶¨Ìõ¼þµÄ»ØÌû£¬µã»÷ÕâÀï²é¿´±¾»°ÌâµÄËùÓлØÌû | |||
fangdy
|
[É̼ҹ©Ó¦]
΢Á÷¿Ø¾«ÃÜѹÁ¦½øÑù±ÃOB1ÔÚPDMSÒºµÎоƬÖвúÉú¿ìËÙ¡¢Îȶ¨µÄÓͰüˮҺµÎ
|
||
|
ÏÞÁ¿ x ÕÅ
Âú x ¿ÉʹÓã»ÓÐЧÆÚ x Ì죻¹ýÆÚ¿ÉÍË |
ÄÚÈÝ
|
΢Á÷¿ØÎ¢ÒºµÎϵͳÊÇ΢Á÷¿ØÐ¾Æ¬ÁìÓòµÄÒ»¸ö·ÖÖ§£¬Æä²ÉÓÃÁ½ÖÖ²»ÏàÈܵÄÁ÷ÌåÔÚ΢¿×µÀµÄ½çÃæ´¦ÐγÉ΢ҺµÎ£¬Î¢ÒºµÎµÄÌå»ýͨ³£ÔÚnl - pl·¶Î§¡£Î¢ÒºµÎÓÉÓÚ¾ßÓÐÌå»ýС¡¢ÎÞ½»²æÎÛȾ¡¢·´Ó¦¿ìËÙ¡¢×°Öüòµ¥¡¢Öظ´ÐԺá¢Ò×ÓÚ¾«È·¿ØÖƵÈÓÅµã¶øµÃµ½ÁË¿ìËÙ·¢Õ¹£¬Æä¹ã·ºÓ¦ÓÃÓÚÉúÎï¡¢»¯Ñ§¡¢Ò½Ñ§¡¢²ÄÁϵÈÁìÓò¡£ ÒºµÎ΢Á÷¿ØÏµÍ³ÖÐÁ½ÏàÁ÷Á÷ÌåÁ÷¶¯µÄ³¤Ê±¼äÎȶ¨ÐÔ¡¢¿ìËÙÏìÓ¦ÐÔ¼°²Ù×÷µÄ±ãЯÐÔ¶ÔÓÚ΢Á÷¿ØÎ¢ÒºµÎÖÆ±¸À´ËµÊDZØÐëÒª¿¼Á¿µÄÒ»¸öÊÂÏî¡£½«Á½Ï໥²»ÏàÈݵÄÁ÷ÌåÎȶ¨¶øÓÖ¿ìËÙµÄÍÆ½øÎ¢Á÷¿ØÐ¾Æ¬µÄͨµÀÄÚʱÐèҪʹÓÃ΢Á÷¿ØÇý¶¯±Ã±ÈÈç¹þ·ð×¢Éä±Ã£¨harvard pump£©¡¢È䶯±Ã¡¢Ñ¹Á¦±Ã£¨elveflow ob1 mk3ѹÁ¦±Ã£¬¾«ÃÜpneuwaveÆøÑ¹±ÃµÈ£©µÈ¡£µ±ÖƱ¸µÄ΢ҺµÎ³ß´çСÓÚ20¦Ìmʱ£¬Ñ¹Á¦Çý¶¯±ÃÒòÆäÒÔÆøÌåѹÁ¦Çý¶¯µÄ¿ìËÙÐÔ¶ø±È×¢Éä±ÃÓкÜÃ÷ÏÔµÄÓÅÊÆ¡£³ýÁËѹÁ¦±ÃÏìÓ¦µÄ¿ìËÙÐÔÍ⣬ѹÁ¦Çý¶¯±Ã»¹¾ßÓкܸߵÄѹÁ¦·Ö±æÂÊ¡¢¼¯³É¶È¸ß¡¢²Ù×÷¼ò±ãµÈÓÅÊÆ¡£ ¶ÔÓڱȽϳ£¼ûµÄÁ½ÏàÁ÷Á÷ÌåÖÆ±¸Î¢Á÷¿ØÎ¢ÒºµÎÀ´½²£¬ÎÒÔڴ˽éÉÜÒ»Ì×΢ҺµÎ·¢ÉúÆ÷Ì××°¡ªDroplet generation pack£¬¸ÃÌ××°¿ÉÂú×ã´ó²¿·Ö΢ҺµÎÖÆ±¸µÄÐèÇó¡£ Î¢Á÷¿ØÒºµÎÓ¦Óà 1¡¢¸ß·Ö×ÓºÏ³É 2¡¢Ï¸°ûÅàÑø 3¡¢pcr 4¡¢Ë«ÖØÎ¢ÈéÒº 5¡¢Ë®Äý½ººÏ³É 6¡¢rnaÐòÁÐ 7¡¢µ¥Ï¸°û·ÖÎö 8¡¢Ò©ÎïÊäÔË ¸Ã΢Á÷¿ØÒºµÎÌ××°Ö÷Òª°üº¬ÈçÏÂ3¼þ¶«Î÷£º 1¡¢Ñ¹Á¦±Ã¿ØÖÆÆ÷/ѹÁ¦±Ã ob1 mk3£¨2 channels - 2 bars£© 2¡¢pdms΢Á÷¿ØÐ¾Æ¬ 3¡¢2¸öÁ÷Á¿´«¸ÐÆ÷ ´ËÍ⣬»¹°üÀ¨ÈçÏÂµÄÆäËû¶«Î÷£º 1¡¢ÓͺͱíÃæ»îÐÔ¼Á - 20 ml £¨hfe 7500 +2%»îÐÔ¼Á£© 2¡¢15 ml´¢Òº³Ø£¬°üº¬´¢Òº³ØµÄ¸Çñ 3¡¢Íâ¾¶od 1/32¡±µ¼¹Ü 4¡¢1/4¡± - 28µÄÊÊÅäÆ÷ 5¡¢luer locksÊÊÅäÆ÷ 6¡¢1/16¡± odÍâ¾¶µÄfep΢Á÷¿ØÌ×¹Ü 7¡¢Ñ¹Á¦Ô´¿ìËÙÁ¬½ÓÌ××° 8¡¢Æø¶¯¾Û°±õ¥£¨pu£©ÈáÐÔ¹Ü 9¡¢ESI elveflowÈí¼þ Elveflow OB1΢Á÷¿ØÑ¹Á¦¿ØÖÆÆ÷/ѹÁ¦±ÃÒòÆä³öÉ«µÄÐÔÄܶø±»ÓÃÓÚÈçÏÂ΢ҺµÎÖÆ±¸µÄÂÛÎÄÖÐ 1¡¢d. weitz et al., macromolecular journal, high-throughput step emulsification for the production of functional materials using a glass microfluidic device 2¡¢a. j. demello et al., lab on a chip, nov 2015, controllable generation and encapsulation of alginate fibers using droplet-based microfluidics 3¡¢g. whyte et al., scientific reports, sept 2017, image-based closed-loop feedback for highly mono-dispersed microdroplet production 4¡¢say hwa tan et al., analytical chemistry, feb 2017, negative pressure induced droplet generationin a microfluidic flow-focusing device ¸ü¼ÓÏêϸµÄÄÚÈݽéÉÜ£¬Çë¹Ø×¢£ºhttps://www.techusci.com/?thread-81-1.html ΢Á÷¿ØÒºµÎ²úÉúʵÑéÁ¬½Óͼ.jpg ΢Á÷¿Ø¾«ÃÜѹÁ¦½øÑù±Ãob1.jpg ΢Á÷¿ØpdmsÒºµÎоƬ.jpg ΢Á÷¿ØÒºÌåÁ÷Á¿´«¸ÐÆ÷mfs.jpg ΢Á÷¿ØpdmsÒºµÎоƬÖвúÉúÒºµÎ.jpg ΢Á÷¿ØÒºµÎ²úÉúÌ××°.jpg |
» ²ÂÄãϲ»¶
ÊÛSCIÒ»ÇøÎÄÕ£¬ÎÒ:8.O.551.O.5.4,¿ÆÄ¿È«,¿ÉÙ¤¼±
ÒѾÓÐ4È˻ظ´
ÊÛSCIÒ»ÇøT0PÎÄÕ£¬ÎÒ:8.O.55.1.O.5.4,¿ÆÄ¿È«,¿É+¼±
ÒѾÓÐ4È˻ظ´
ÊÛSCIÒ»ÇøT0PÎÄÕ£¬ÎÒ:8.O.55.1.O.5.4,¿ÆÄ¿È«,¿É+¼±
ÒѾÓÐ4È˻ظ´
ÊÛSCIÒ»ÇøT0PÎÄÕ£¬ÎÒ:8O.55.1.O.5.4,¿ÆÄ¿ÆëÈ«,¿É+¼±
ÒѾÓÐ4È˻ظ´
2026Äê8ÔÂ25ÈÕ¹ú×ÔÈ»·Å°ñǰͻȻÊÕµ½ÁÐÈëÆÀÉóר¼ÒÓʼþ£¬ÓйØÏµÂð£¿
ÒѾÓÐ20È˻ظ´
½ñÌìÎñί»á¿ªÍêÁË£¬Ã÷Ìì³ö½á¹ûÂð
ÒѾÓÐ22È˻ظ´
ÔÚ¼á±ù»¹¸Ç×ű±º£µÄʱºò£¬ÎÒ¿´µ½ÁËŷŵÄ÷»¨¡£
ÒѾÓÐ9È˻ظ´
Ã÷ÌìÓ¦¸Ã¿É²éÁË£¡£¿
ÒѾÓÐ6È˻ظ´
ÓÐûÓдóÉñ°ïÎÒ¿´¿´»ù½ð´úÂë
ÒѾÓÐ10È˻ظ´
·Å°ñǰµÄ²»µ¶¨
ÒѾÓÐ19È˻ظ´
966345490
гæ (ÖªÃû×÷¼Ò)
- Ó¦Öú: 0 (Ó×¶ùÔ°)
- ½ð±Ò: 2094.6
- É¢½ð: 4000
- Ìû×Ó: 5037
- ÔÚÏß: 353.7Сʱ
- ³æºÅ: 23621718
- ×¢²á: 2020-10-01
- רҵ: ÎÞ»ú»¯Ñ§
694Â¥2026-08-17 00:52:01
2Â¥2019-04-03 19:55:20
4Â¥2019-04-03 22:52:26
6Â¥2019-04-04 22:15:06



»Ø¸´´ËÂ¥

20