simufact welding计算中出现错误,退出号为1009,请问这是什么原因? 已有3人参与
|
|
退出号详解如下 9999 1009 Error encountered in stress recovery. The output will reveal which element has a particular problem. The error is usually due to excessive deformation in the element. Note that this can occur during the iterative process, so that it is not always possible to visualize the excessive deformation. Check the material behavior and the magnitude of the incremental loads. Suggestion : ------------ Activate the cut-back feature if using the AUTO LOAD, AUTO STEP or AUTO INCREMENT solution schemes. This will allow the analysis to automatically cut down the time step and to try again from the end of the last converged increment. For the AUTO LOAD procedure, the increment numbers are maintained as specified in the input. |