| 查看: 5063 | 回复: 3 | ||
[求助]
求助?关于Design Expert软件操作应用中的lack of fit无F值和p值
|
|
关于Design Expert软件的应用 就是在用Design Expert软件进行数据处理后,ANOVA中的lack of fit一项中的F值和p值没有显示出来,并且pure error那一项显示是0,要怎么解决这个问题? Use your mouse to right click on individual cells for definitions. Response 1 相对干燥能耗 ANOVA for Response Surface Quadratic Model Analysis of variance table [Partial sum of squares - Type III] Sum of Mean F p-value Source Squares df Square Value Prob > F Model 581.32 9 64.59 5.09 0.0217 significant A-表面温度 100.72 1 100.72 7.93 0.0259 B-转换点含水率 86.84 1 86.84 6.84 0.0347 C-微波功率 79.28 1 79.28 6.24 0.0411 AB 0.68 1 0.68 0.053 0.8240 AC 0.095 1 0.095 7.468E-003 0.9336 BC 25.18 1 25.18 1.98 0.2019 A^2 0.25 1 0.25 0.020 0.8927 B^2 93.30 1 93.30 7.35 0.0302 C^2 177.71 1 177.71 14.00 0.0073 Residual 88.88 7 12.70 Lack of Fit 88.88 3 29.63 Pure Error 0.000 4 0.000 Cor Total 670.20 16 The Model F-value of 5.09 implies the model is significant. There is only a 2.17% chance that a "Model F-Value" this large could occur due to noise. Values of "Prob > F" less than 0.0500 indicate model terms are significant. In this case A, B, C, B++2+-, C++2+- are significant model terms. Values greater than 0.1000 indicate the model terms are not significant. If there are many insignificant model terms (not counting those required to support hierarchy), model reduction may improve your model. Std. Dev. 3.56 R-Squared 0.8674 Mean 28.49 Adj R-Squared 0.6969 C.V. % 12.51 Pred R-Squared -1.1220 PRESS 1422.15 Adeq Precision 6.382 A negative "Pred R-Squared" implies that the overall mean is a better predictor of your response than the current model. "Adeq Precision" measures the signal to noise ratio. A ratio greater than 4 is desirable. Your ratio of 6.382 indicates an adequate signal. This model can be used to navigate the design space. Coefficient Standard 95% CI 95% CI Factor Estimate df Error Low High VIF Intercept 33.88 1 1.59 30.11 37.65 A-表面温度 -3.55 1 1.26 -6.53 -0.57 1.00 B-转换点含水率 3.29 1 1.26 0.32 6.27 1.00 C-微波功率 -3.15 1 1.26 -6.13 -0.17 1.00 AB -0.41 1 1.78 -4.62 3.80 1.00 AC 0.15 1 1.78 -4.06 4.37 1.00 BC -2.51 1 1.78 -6.72 1.70 1.00 A^2 -0.24 1 1.74 -4.35 3.86 1.01 B^2 -4.71 1 1.74 -8.81 -0.60 1.01 C^2 -6.50 1 1.74 -10.60 -2.39 1.01 Final Equation in Terms of Coded Factors: 相对干燥能耗 = +33.88 -3.55 * A +3.29 * B -3.15 * C -0.41 * A * B +0.15 * A * C -2.51 * B * C -0.24 * A^2 -4.71 * B^2 -6.50 * C^2 Final Equation in Terms of Actual Factors: 相对干燥能耗 = -110.47085 +0.50586 * 表面温度 +480.92139 * 转换点含水率 +0.21498 * 微波功率 -0.82280 * 表面温度 * 转换点含水率 +1.53968E-004 * 表面温度 * 微波功率 -0.12545 * 转换点含水率 * 微波功率 -9.71335E-003 * 表面温度^2 -470.72663 * 转换点含水率^2 -1.62417E-004 * 微波功率^2 The Diagnostics Case Statistics Report has been moved to the Diagnostics Node. In the Diagnostics Node, Select Case Statistics from the View Menu. Proceed to Diagnostic Plots (the next icon in progression). Be sure to look at the: 1) Normal probability plot of the studentized residuals to check for normality of residuals. 2) Studentized residuals versus predicted values to check for constant error. 3) Externally Studentized Residuals to look for outliers, i.e., influential values. 4) Box-Cox plot for power transformations. If all the model statistics and diagnostic plots are OK, finish up with the Model Graphs icon. |
» 猜你喜欢
快农历七夕节了,轻松一下,男人悄悄话,女施主请不要进来。
已经有3人回复
哪位老哥知道今年的国自然具体哪一天放榜?
已经有9人回复
欢迎发来filecode的Mz6后的代码验证其规律
已经有72人回复
咱们一起用铁证分析2026国家社科基金中标与否
已经有26人回复
我的国基提前知道中了,可是同事的操作让我实在接受不了,怎么会有这样的人
已经有16人回复
有时候,自然基金真的不能太认真 (我的申报经验)
已经有12人回复
招聘 金属平磨液,抛光液研发工程师
已经有3人回复
时间戳又变了8-15
已经有23人回复
filecode=后面第一个是大写字母
已经有7人回复
filecode
已经有12人回复
2楼2018-03-01 13:51:56
3楼2018-03-20 20:05:28
4楼2019-08-07 23:47:58










回复此楼