ͨ¹ýÄÚ²¿ÌØÊâµÄ½á¹¹£¬Äܹ»Ê¹ÆøÁ÷¾ùÔȵķֲ¼£¬´Ó¶øÊ¹µÃÄÜÁ¿Ê¹µÃRTOÄÜÁ¿ÏûºÄ×îС»¯£¬ÐîÈÈЧÂÊÔÚ92.5%ÒÔÉÏ ¢ÙÈÈ·çÅÔ·µÄÉè¼Æ¿ÉÒÔ±£Ö¤ÔÚ¸ßŨ¶ÈµÄÆøÌåȼÉÕʱ£¬¶àÓàµÄÈÈÁ¿Ö±½Óͨ¹ýÅÔ·ÅÅ·Å£¬¼õÉÙ¶ÔÉ豸ºÍÌմɵÄÈȳå»÷¡£ ¢Ú ÔÚ½ô¼±Çé¿öÏ£¬Î²Æø¿ÉÒÔͨ¹ýÈë¿ÚÅſշ§Ö±½ÓÅÅ·Å¡£×èÖ¹Î²Æø½øÈë´¦ÀíÉ豸¡£ ¢Ù ÖØÁ¿ÓëÕ¼µØÃæ»ý×îС»¯ ¢Ú ¸ù¾ÝÏÖ³¡Ìõ¼þ¿ÉÉè¼ÆÎªÔ²Ðλò·½ÐÎ |
» ²ÂÄãϲ»¶
±¾ÈË¿¼085602 »¯Ñ§¹¤³Ì ר˶
ÒѾÓÐ23È˻ظ´
Çóµ÷¼ÁԺУÐÅÏ¢
ÒѾÓÐ4È˻ظ´
085600²ÄÁÏÓ뻯¹¤306
ÒѾÓÐ4È˻ظ´
286Çóµ÷¼Á
ÒѾÓÐ10È˻ظ´
328Çóµ÷¼Á£¬Ó¢ÓïÁù¼¶551£¬ÓпÆÑоÀú
ÒѾÓÐ9È˻ظ´
Ò»Ö¾Ô¸±±¾©»¯¹¤´óѧ070300 ѧ˶336Çóµ÷¼Á
ÒѾÓÐ4È˻ظ´
286·ÖÈ˹¤ÖÇÄÜרҵÇëÇóµ÷¼ÁÔ¸Òâ¿ç¿¼£¡
ÒѾÓÐ8È˻ظ´
×ÊÔ´Óë»·¾³ µ÷¼ÁÉêÇë(333·Ö)
ÒѾÓÐ5È˻ظ´
280Çóµ÷¼Á
ÒѾÓÐ12È˻ظ´
269ר˶Çóµ÷¼Á
ÒѾÓÐ5È˻ظ´

rockingyouth
¾èÖú¹ó±ö (ÕýʽдÊÖ)
- Ó¦Öú: 8 (Ó×¶ùÔ°)
- ½ð±Ò: 59.1
- É¢½ð: 16
- ºì»¨: 2
- Ìû×Ó: 519
- ÔÚÏß: 203.6Сʱ
- ³æºÅ: 160833
- ×¢²á: 2006-01-09
- ÐÔ±ð: GG
- רҵ: ÓлúºÏ³É
ÇëÇó+½ð±Ò
¡ï ¡ï ¡ï ¡ï ¡ï
gaihengxu(½ð±Ò+5,VIP+0):лл
gaihengxu(½ð±Ò+5,VIP+0):лл
|
Through the special internal structure, it can make airflow distribution average and minimize the RTO power consumption accordingly, and improve the efficiency of thermal storage more than 92.5 percent. 1.Hot air bypass design ensure that excess heat directly ejects through the bypass and reduces thermal shock to the equipment and the ceramic. 2.In case of emergency, exhausts can be exported directly through entrance emptying valve and inhibits exhausts enter processing equipment. 1.minimize the weight and area 2.According to the on-site conditions it can be designed for round or square |
5Â¥2009-01-01 09:45:12
rockingyouth
¾èÖú¹ó±ö (ÕýʽдÊÖ)
- Ó¦Öú: 8 (Ó×¶ùÔ°)
- ½ð±Ò: 59.1
- É¢½ð: 16
- ºì»¨: 2
- Ìû×Ó: 519
- ÔÚÏß: 203.6Сʱ
- ³æºÅ: 160833
- ×¢²á: 2006-01-09
- ÐÔ±ð: GG
- רҵ: ÓлúºÏ³É
¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï ¡ï
gaihengxu(½ð±Ò+10,VIP+0):лл
gaihengxu(½ð±Ò+10,VIP+0):лл
|
Through the special internal structure, it can make airflow distribution average and minimize the RTO power consumption accordingly, and improve the efficiency of thermal storage more than 92.5 percent. 1.Hot air bypass design ensure that excess heat directly ejects through the bypass and reduces thermal shock to the equipment and the ceramic. 2.In case of emergency, exhausts can be exported directly through entrance emptying valve and inhibits exhausts enter processing equipment. 1.minimize the weight and area 2.According to the on-site conditions it can be designed for round or square |
4Â¥2009-01-01 09:44:05













»Ø¸´´ËÂ¥