[交流] 【求助】金纳米颗粒的共振光散射如何测?

看文献报道说是用荧光分光光度计可以测,具体是这样描述的:

The PRLS spectra were obtained by scanning simultaneously
the excitation and emission monochromators of the F-4500
spectrofluorometer (Hitachi, Tokyo, Japan) from 300 to 700 nm
(namely, Δλ ) 0 nm), and all PRLS measurements were made
with a 5.0 nm slit width of the excitation and the emission of the
spectrofluorometer. The PRLS intensity was measured at the
maximum PRLS peak of 555 nm.

那位懂得同仁给具体解释一下?

[ Last edited by 大笨猪和聪明羊 on 2008-12-7 at 22:27 ]
回复此楼
日进一小步
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖

soaring0331

金虫 (正式写手)

★ ★
kqy920(金币+2,VIP+0):感谢应助! 2-16 09:31
使用同步荧光模式扫描,然后选在激发波长和发射波长相等。
例如,你要扫描300-700纳米的散射光谱,选择start ex=300nm, start em=300nm, end ex =700nm; 若扫描400-500nm 的,则设定成start ex=400nm, start em=400nm, end ex =500nm
2楼2009-02-16 09:22:51
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖

hyzq

木虫 (正式写手)

学习,很有启发
3楼2009-05-06 18:54:22
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖

wuwt

木虫 (正式写手)

不错,学习了
4楼2009-05-07 03:03:32
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖