24小时热门版块排行榜    

查看: 1219  |  回复: 3

凯旋1029

铁虫 (初入文坛)

[求助] 在CP运行中关于Error in routine ortho (1): ortho went bananas报错

我在运行cp.x过程中,遇到了“ortho went bananas”这个报错,弄了很久都没找到问题在哪里,有人能帮我看一下么?下面是我的输入文件:
  &CONTROL                                                                     
  calculation = 'cp'                                   
  dt =   2.0                                          
  iprint = 10                                                   
  isave = 100                                               
  ndr = 52                                               
  ndw = 53                                                
  nstep = 10000                                         
  outdir = './out/'                              
  prefix = 'ABX3wfopt'                                 
  restart_mode = 'restart'                       
  verbosity = 'high'                     
  wf_collect = .false.
  ekin_conv_thr=1.e-5,
  etot_conv_thr=1.e-7,
  forc_conv_thr=1.e-5,
  pseudo_dir='./'                                             
/                                                   
&SYSTEM                                               
  ecutrho =   120.0                                    
  ecutwfc =   30.0                     
  ibrav = 7         
  celldm(1)=33.1948  
  celldm(3)=1.4459                                                      
  nat = 96                                       
  ntyp = 5                                                        
  nr1b = 24                                    
  nr2b = 24
  nr3b = 24                                                              
  /                                          
&ELECTRONS                                               
  electron_damping =   0.1                           
  electron_dynamics = 'damp'                        
  emass =   400                                      
  emass_cutoff =   3.0                              
  electron_temperature = 'not_controlled'
/                                                         
&IONS                                          
  ion_dynamics = 'damp'                       
  ion_damping=0.02                           
  ion_temperature='not_controlled'               
/                                                     
ATOMIC_SPECIES                 
Pb 207.2 Pb.pbe-dn-rrkjus_psl.0.2.2.UPF              
I 126.9 I.pbe-n-rrkjus_psl.0.2.UPF                  
C 12.0 C.pbe-n-rrkjus_psl.0.1.UPF                    
N 14.0 N.pbe-n-rrkjus_psl.0.1.UPF         
H 1.0 H.pbe-rrkjus_psl.0.1.UPF                                                            
ATOMIC_POSITIONS angstrom                          
Pb       4.2403    4.7040    6.2142              
Pb      13.0233    4.7040    6.2142              
Pb       4.2403   13.4870    6.2142              
Pb      13.0233   13.4870    6.2142              
Pb       4.2403    4.7040   18.9132              
Pb      13.0233    4.7040   18.9132              
Pb       4.2403   13.4870   18.9
谢谢啦
回复此楼
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖

凯旋1029

铁虫 (初入文坛)

有没有大神看一下
2楼2016-11-03 08:54:06
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖

雪中谷雨

新虫 (初入文坛)

把dr的值改小些试试,这是不收敛

发自小木虫Android客户端
3楼2017-03-31 10:30:43
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖

雪中谷雨

新虫 (初入文坛)

dt或者是ortho增加的方向相反,你试试

发自小木虫Android客户端
4楼2017-03-31 10:33:28
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖