[交流]
USP中关于沉降菌检验频率
|
|||
| 各位专家,我国GMP规定沉降菌与浮游菌只检一样即可,请问USP是如何规定的,浮游菌在各种环境级别的检测频率是多少?100000级的标准是多少? |
» 猜你喜欢
心脉受损
已经有7人回复
之前让一硕士生水了7个发明专利,现在这7个获批发明专利的维护费可从哪儿支出哈?
已经有9人回复
博士申请都是内定的吗?
已经有8人回复
博士读完未来一定会好吗
已经有32人回复
读博
已经有5人回复
投稿精细化工
已经有4人回复
高职单位投计算机相关的北核或SCI四区期刊推荐,求支招!
已经有4人回复
导师想让我从独立一作变成了共一第一
已经有9人回复
Springer期刊投稿求助
已经有4人回复

huigenghao
至尊木虫 (著名写手)
- 应助: 15 (小学生)
- 贵宾: 0.126
- 金币: 22056
- 散金: 56
- 红花: 13
- 帖子: 1681
- 在线: 241.4小时
- 虫号: 29283
- 注册: 2003-11-23
- 性别: GG
- 专业: 知识管理
|
Surface Air System Sampler— This integrated unit consists of an entry section that accommodates an agar contact plate. Immediately behind the contact plate is a motor and turbine that pulls air through the unit's perforated cover over the agar contact plate and beyond the motor, where it is exhausted. Multiple mounted assemblies are also available. Gelatin Filter Sampler— The unit consists of a vacuum pump with an extension hose terminating in a filter holder that can be located remotely in the critical space. The filter consists of random fibers of gelatin capable of retaining airborne microorganisms. After a specified exposure time, the filter is aseptically removed and dissolved in an appropriate diluent and then plated on an appropriate agar medium to estimate its microbial content. Settling Plates— This method is still widely used as a simple and inexpensive way to qualitatively assess the environments over prolonged exposure times. The exposure of open agar-filled Petri dishes, or settling plates, is not to be used for quantitative estimations of the microbial contamination levels of critical enviroments. One of the major limitations of mechanical air samplers is the limitation in sample size of air being sampled. Where the microbial level in the air of a controlled environment is expected to contain not more than three cfu per cubic meter, several cubic meters of air should be tested if results are to be assigned a reasonable level of precision and accuracy. Often this is not practical. To show that microbial counts present in the environment are not increasing over time, it might be necessary to extend the time of sampling to determine if the time of sampling is a limiting factor or not. Typically, slit-to-agar samplers have an 80-liter-per-minute sampling capacity (the capacity of the surface air system is somewhat higher). If one cubic meter of air is tested, then it would require an exposure time of 15 minutes. It may be necessary to use sampling times in excess of 15 minutes to obtain a representative environmental sample. Although there are samplers reported to be capable of very high sampling volume rates, consideration in these situations should be given to the potential for disruption of the airflow patterns in any critical area or to the creation of a turbulence that could increase the probability of contamination. For centrifugal air samplers, a number of earlier studies showed that the samples demonstrated a selectivity for larger particles. The use of this type of sampler may have resulted in higher airborne counts than the other types of air samplers because of that inherent selectivity. When selecting a centrifugal sampler, the effect of the sampler on the linearity of the airflow in the controlled zone where it is placed for sampling should be taken into consideration. Regardless of the type of sampler used, the use of a remote probe requires determining that the extra tubing does not have an adverse effect on the viable airborne count. This effect should either be eliminated or, if this is not possible, a correction factor should be introduced in the reporting of results. Methodology and Equipment for Sampling of Surfaces for Quantitation of Viable Microbial Contaminants in Controlled Environments Another component of the microbial environmental control program in controlled environments is surface sampling of equipment, facilities, and personnel gear used in these environments. The standardization of surface sampling methods and procedures has not been as widely addressed in the pharmaceutical industry as the standardization of air sampling procedures.3 To minimize disruptions to critical operations, surface sampling is performed at the conclusion of operations. Surface sampling may be accomplished by the use of contact plates or by the swabbing method. Surface monitoring is generally performed on areas that come in contact with the product and on areas adjacent to those contact areas. Contact plates filled with nutrient agar are used when sampling regular or flat surfaces and are directly incubated at the appropriate time for a given incubation temperature for quantitation of viable counts. Specialized agar can be used for specific quantitation of fungi, spores, etc. The swabbing method may be used for sampling of irregular surfaces, especially for equipment. Swabbing is used to supplement contact plates for regular surfaces. The swab is then placed in an appropriate diluent and the estimate of microbial count is done by plating of an appropriate aliquot on or in specified nutrient agar. The area to be swabbed is defined using a sterile template of appropriate size. In general, it is in the range of 24 to 30 cm2. The microbial estimates are reported per contact plate or per swab. Culture Media and Diluents Used for Sampling or Quantitation of Microorganisms The type of medium, liquid or solid, that is used for sampling or quantitation of microorganisms in controlled environments will depend on the procedure and equipment used. A commonly used all-purpose medium is Soybean–Casein Digest Agar when a solid medium is needed. Other media, liquid or solid, are listed below. Liquid Media* Solid Media* Tryptone saline Soybean-casein digest agar Peptone water Nutrient agar Buffered saline Tryptone glucose extract agar Buffered gelatin Lecithin agar Enriched buffered gelatin Brain heart infusion agar Brain heart infusion Contact plate agar Soybean-casein medium * Liquid and solid media are sterilized using a validated process. These media are commercially available in dehydrated form. They are also available in ready-to-use form. When disinfectants or antibiotics are used in the controlled area, consideration should be given to using media with appropriate inactivating agents. Alternative media to those listed can be used provided that they are validated for the purpose intended. Identification of Microbial Isolates from the Environmental Control Program The environmental control program includes an appropriate level of identification of the flora obtained from sampling. A knowledge of the normal flora in controlled environments aids in determining the usual microbial flora anticipated for the facility being monitored; evaluating the effectiveness of the cleaning and sanitization procedures, methods, and agents; and recovery methods. The information gathered by an identification program can also be useful in the investigation of the source of contamination, especially when the Action levels are exceeded. Identification of isolates from critical areas and areas immediate to these critical areas should take precedence over identification of microorganisms from noncritical areas. Identification methods should be verified, and ready-to-use kits should be qualified for their intended purpose (see Critical Factors Involved in the Design and Implementation of Environmental Control Program). Operational Evaluation of the Microbiological Status of Aseptically Filled Products in Clean Rooms and Other Controlled Environments The controlled environment is monitored through an appropriate environmental monitoring program. To assure that minimal bioburden is achieved, additional information on the evaluation of the microbiological status of the controlled environment can be obtained by the use of media fills. An acceptable media fill shows that a successful simulated product run can be conducted on the manufacturing line at that point in time. However, other factors are important, such as appropriate construction of facilities, environmental monitoring and training of personnel. When an aseptic process is developed and installed, it is generally necessary to qualify the microbiological status of the process by running at least three successful consecutive media fills. A media fill utilizes growth medium in lieu of products to detect the growth of microorganisms. Issues in the development of a media fill program that should be considered are the following: media-fill procedures, media selection, fill volume, incubation, time and temperature, inspection of filled units, documentation, interpretation of results, and possible corrective actions required. Since a media fill is designed to simulate aseptic processing of a specified product, it is important that conditions during a normal product run are in effect during the media fill. This includes the full complement of personnel and all the processing steps and materials that constitute a normal production run. During the conduct of media fill, various predocumented interventions that are known to occur during actual product runs should be planned (e.g., changing filling needles, fixing component jams). Alternatively, in order to add a safety margin, a combination of possible conditions can be used. Examples may include frequent start and stop sequences, unexpected repair of processing system, replacement of filters, etc. The qualification of an aseptic process need not be done for every product, but should be done for each processing line. Since the geometry of the container (size as well as opening of the container) and the speed of the line are factors that are variable in the use of an aseptic processing line, appropriate combination of these factors, preferably at the extremes, should be used in the qualification of the line. A rationale for products used should be documented. The 1987 FDA Guideline on Sterile Drug Products Produced by Aseptic Processing indicates that media-fill runs be done to cover all production shifts for line/product/container combinations. This guideline should be considered not only for qualification media-fill runs, but also for periodic reevaluation or revalidation. Media fill programs should also simulate production practices over extended runs. This can be accomplished by doing media-fill runs at the end of production runs. In general, an all-purpose, rich medium such as Soybean Casein Broth that has been checked for growth promotion with a battery of indicator organisms (see Sterility Tests 71) at a level of below 100 cfu/unit, can be used. Isolates from the controlled environment where aseptic processing is to be conducted may also be used. Following the aseptic processing of the medium, the filled containers are incubated at 22.5 ± 2.5 or at 32.5 ± 2.5. All media filled containers should be incubated for a minimum of 14 days. If two temperatures are used for incubation of media filled samples, then these filled containers should be incubated for at least 7 days at each temperature. Following incubation, the medium-filled containers should be inspected for growth. Media filled isolates are identified by genus and, when possible, by species in order to investigate the sources of contamination. |
6楼2008-07-27 11:22:46

2楼2008-07-25 15:24:28
huigenghao
至尊木虫 (著名写手)
- 应助: 15 (小学生)
- 贵宾: 0.126
- 金币: 22056
- 散金: 56
- 红花: 13
- 帖子: 1681
- 在线: 241.4小时
- 虫号: 29283
- 注册: 2003-11-23
- 性别: GG
- 专业: 知识管理
★ ★ ★ ★ ★ ★ ★ ★ ★ ★
feng1619(金币+10,VIP+0):非常感谢你的热心和你提供的资料!
feng1619(金币+10,VIP+0):非常感谢你的热心和你提供的资料!
|
再usp 116节有明确的说明,下面是29版的内容,请你参考 U.S. PHARMACOPEIA USP29 1116 MICROBIOLOGICAL EVALUATION OF CLEAN ROOMS AND OTHER CONTROLLED ENVIRONMENTS The purpose of this informational chapter is to review the various issues that relate to aseptic processing of bulk drug substances, dosage forms, and in certain cases, medical devices; and to the establishment, maintenance, and control of the microbiological quality of controlled environments. This chapter includes discussions on (1) the classification of a clean room based on particulate count limits; (2) microbiological evaluation programs for controlled environments; (3) training of personnel; (4) critical factors in design and implementation of a microbiological evaluation program; (5) development of a sampling plan; (6) establishment of microbiological Alert and Action levels; (7) methodologies and instrumentation used for microbiological sampling; (8) media and diluents used; (9) identification of microbial isolates; (10) operational evaluation via media fills; and (11) a glossary of terms. Excluded from this chapter is a discussion of controlled environments for use by licensed pharmacies in the preparation of sterile products for home use, which is covered under Pharmaceutical Compounding—Sterile Preparations 797. There are alternative methods to assess and control the microbiological status of controlled environments for aseptic processing. Numerical values included in this chapter are not intended to represent absolute values or specifications, but are informational. Given the variety of microbiological sampling equipment and methods, one cannot reasonably suggest that the attainment of these values guarantees the needed level of microbial control or that excursions beyond values in this chapter indicate a loss of control. The improper application of microbiological sampling and analysis may cause significant variability and the potential for inadvertent contamination. Sampling media and devices, and methods indicated in this chapter, are not specifications but only informational. A large proportion of sterile products are manufactured by aseptic processing. Because aseptic processing relies on the exclusion of microorganisms from the process stream and the prevention of microorganisms from entering open containers during filling, product bioburden as well as microbial bioburden of the manufacturing environment are important factors relating to the level of sterility assurance of these products. Establishment of Clean Room Classifications The design and construction of clean rooms and controlled environments are covered in Federal Standard 209E. This standard of air cleanliness is defined by the absolute concentration of airborne particles. Methods used for the assignment of air classification of controlled environments and for monitoring of airborne particulates are included. This federal document only applies to airborne particulates within a controlled environment and is not intended to characterize the viable or nonviable nature of the particles. The application of Federal Standard 209E to clean rooms and other controlled environments in the pharmaceutical industry has been used by manufacturers of clean rooms to provide a specification for building, commissioning, and maintaining these facilities. However, data available in the pharmaceutical industry provide no scientific agreement on a relationship between the number of nonviable particulates and the concentration of viable microorganisms. The criticality of the number of nonviable particulates in the electronic industry makes the application of Federal Standard 209E a necessity, while the pharmaceutical industry has a greater concern for viable particulates (i.e., microorganisms) rather than total particulates as specified in Federal Standard 209E. A definite concern for counts of total particulates in injectable products exists in the pharmaceutical industry (see Particulate Matter in Injections 788). The rationale that the fewer particulates present in a clean room, the less likely it is that airborne microorganisms will be present is accepted and can provide pharmaceutical manufacturers and builders of clean rooms and other controlled environments with engineering standards in establishing a properly functioning facility. Federal Standard 209E, as applied in the pharmaceutical industry is based on limits of all particles with sizes equal to or larger than 0.5 µm. Table 1 describes Airborne Particulate Cleanliness Classes in Federal Standard 209E as adapted to the pharmaceutical industry. The pharmaceutical industry deals with Class M3.5 and above. Class M1 and M3 relate to the electronic industry and are shown in Table 1 for comparison purposes. It is generally accepted that if fewer particulates are present in an operational clean room or other controlled environment, the microbial count under operational conditions will be less, provided that there are no changes in airflow, temperature, and humidity. Clean rooms are maintained under a state of operational control on the basis of dynamic (operational) data. Table 1. Airborne Particulate Cleanliness Classes* Class Name Particles equal to and larger than 0.5 µm SI U.S. (m3) (ft3) Customary M1 — 10 0.283 M1.5 1 35.3 1 M2 — 100 2.8 M2.5 10 353 10 M3 — 1,000 28.3 M3.5 100 3,530 100 M4 — 10,000 283 M4.5 1,000 35,300 1,000 M5 — 100,000 2,830 M5.5 10,000 353,000 10,000 M6 1,000,000 28,300 M6.5 100,000 3,530,000 100,000 M7 — 10,000,000 283,000 * Adapted from U.S. Federal Standard 209E, September 11, 1992—“Airborne Particulate Cleanliness Classes in Clean Rooms and Clean Zones.” |
3楼2008-07-27 11:17:51
huigenghao
至尊木虫 (著名写手)
- 应助: 15 (小学生)
- 贵宾: 0.126
- 金币: 22056
- 散金: 56
- 红花: 13
- 帖子: 1681
- 在线: 241.4小时
- 虫号: 29283
- 注册: 2003-11-23
- 性别: GG
- 专业: 知识管理
|
Importance of a Microbiological Evaluation Program for Controlled Environments Monitoring of total particulate count in controlled environments, even with the use of electronic instrumentation on a continuous basis, does not provide information on the microbiological content of the environment. The basic limitation of particulate counters is that they measure particles of 0.5 µm or larger. While airborne microorganisms are not free-floating or single cells, they frequently associate with particles of 10 to 20 µm. Particulate counts as well as microbial counts within controlled environments vary with the sampling location and the activities being conducted during sampling. Monitoring the environment for nonviable particulates and microorganisms is an important control function because they both are important in achieving product compendial requirements for Particulate Matter and Sterility under Injections 1. Microbial monitoring programs for controlled environments should assess the effectiveness of cleaning and sanitization practices by and of personnel that could have an impact on the bioburden of the controlled environment. Microbial monitoring, regardless of how sophisticated the system may be, will not and need not identify and quantitate all microbial contaminants present in these controlled environments. However, routine microbial monitoring should provide sufficient information to ascertain that the controlled environment is operating within an adequate state of control. Environmental microbial monitoring and analysis of data by qualified personnel will permit the status of control to be maintained in clean rooms and other controlled environments. The environment should be sampled during normal operations to allow for the collection of meaningful data. Microbial sampling should occur when materials are in the area, processing activities are ongoing, and a full complement of operating personnel is on site. Microbial monitoring of clean rooms and some other controlled environments, when appropriate, should include quantitation of the microbial content of room air, compressor air that enters the critical area, surfaces, equipment, sanitization containers, floors, walls, and personnel garments (e.g., gowns and gloves). The objective of the microbial monitoring program is to obtain representative estimates of bioburden of the environment. When data are compiled and analyzed, any trends should be evaluated by trained personnel. While it is important to review environmental results on the basis of recommended and specified frequency, it is also critical to review results over extended periods to determine whether trends are present. Trends can be visualized through the construction of statistical control charts that include alert and action levels. The microbial control of controlled environments can be assessed, in part, on the basis of these trend data. Periodic reports or summaries should be issued to alert the responsible manager. When the specified microbial level of a controlled environment is exceeded, a documentation review and investigation should occur. There may be differences in the details of the investigation, depending on the type and processing of the product manufactured in the room. Investigation should include a review of area maintenance documentation; sanitization documentation; the inherent physical or operational parameters, such as changes in environmental temperature and relative humidity; and the training status of personnel involved. Following the investigation, actions taken may include reinforcement of training of personnel to emphasize the microbial control of the environment; additional sampling at increased frequency; additional sanitization; additional product testing; identification of the microbial contaminant and its possible source; and an evaluation of the need to reassess the current standard operating procedures and to revalidate them, if necessary. Based on the review of the investigation and testing results, the significance of the microbial level being exceeded and the acceptability of the operations or products processed under that condition may be ascertained. Any investigation and the rationale for the course of action should be documented and included as part of the overall quality management system. A controlled environment such as a clean zone or clean room is defined by certification according to a relevant clean room operational standard. Parameters that are evaluated include filter integrity, air velocity, air patterns, air changes, and pressure differentials. These parameters can affect the microbiological bioburden of the clean room operation. The design, construction, and operation of clean rooms varies greatly, making it difficult to generalize requirements for these parameters. An example of a method for conducting a particulate challenge test to the system by increasing the ambient particle concentration in the vicinity of critical work areas and equipment has been developed by Ljungquist and Reinmuller.1 First, smoke generation allows the air movements to be visualized throughout a clean room or a controlled environment. The presence of vortices or turbulent zones can be visualized, and the airflow pattern may be fine-tuned to eliminate or minimize undesirable effects. Then, particulate matter is generated close to the critical zone and sterile field. This evaluation is done under simulated production conditions, but with equipment and personnel in place. Proper testing and optimization of the physical characteristics of the clean room or controlled environment is essential prior to completion of the validation of the microbiological monitoring program. Assurance that the controlled environment is operating adequately and according to its engineering specifications will give a higher assurance that the bioburden of the environment will be appropriate for aseptic processing. These tests should be repeated during routine certification of the clean room or controlled environment and whenever changes made to the operation, such as personnel flow, processing, operation, material flow, air-handling systems, or equipment layout, are determined to be significant. Training of Personnel Aseptically processed products require manufacturers to pay close attention to detail and to maintain rigorous discipline and strict supervision of personnel in order to maintain the level of environmental quality appropriate for the sterility assurance of the final product. Training of all personnel working in controlled environments is critical. This training is equally important for personnel responsible for the microbial monitoring program, where contamination of the clean working area could inadvertently occur during microbial sampling. In highly automated operations, the monitoring personnel may be the employees who have the most direct contact with the critical zones within the processing area. Monitoring of personnel should be conducted before or after working in the processing area. Microbiological sampling has the potential to contribute to microbial contamination due to inappropriate sampling techniques. A formal personnel training program is required to minimize this risk. This formal training should be documented for all personnel entering controlled environments. Management of the facility must assure that all personnel involved in operations in clean rooms and controlled environments are well versed in relevant microbiological principles. The training should include instruction on the basic principles of aseptic processing and the relationship of manufacturing and handling procedures to potential sources of product contamination. This training should include instruction on the basic principles of microbiology, microbial physiology, disinfection and sanitation, media selection and preparation, taxonomy, and sterilization as required by the nature of personnel involvement in aseptic processing. Personnel involved in microbial identification will require specialized training on required laboratory methods. Additional training on the management of the environmental data collected must be provided to personnel. Knowledge and understanding of applicable standard operating procedures is critical, especially those standard operating procedures relating to corrective measures that are taken when environmental conditions so dictate. Understanding of regulatory compliance policies and each individual's responsibilities with respect to good manufacturing practices (GMPs) should be an integral part of the training program as well as training in conducting investigations and in analyzing data. The major source of microbial contamination of controlled environments is the personnel. Contamination can occur from the spreading of microorganisms by individuals, particularly those with active infections. Only healthy individuals should be permitted access to controlled environments. |