24小时热门版块排行榜    

查看: 1859  |  回复: 24
当前只显示满足指定条件的回帖,点击这里查看本话题的所有回帖

夏天的娃

金虫 (小有名气)

[求助] 气相色谱测含有不挥发液体样品中的挥发物质含量时该如何处理?

大家好!
小虫需要测液体样品的浓度,组分是1个脂肪烃1个芳香烃再加上1个液态盐。液态盐高沸点,300度也不气化,不过我只需要知道2个烃的相对浓度,但是盐流入GC柱子的话肯定会堵柱子呀!!
但是在许多外文文献都有使用GC去测我这种体系的含量,只是在色谱上加了别的东西处理一下,我搜搜了一下相关信息很少呢,好像有用“在线过滤器”,“预柱”,但是供应信息很少,预柱一般是HPLC用的多。因此发帖请教大虫有什么东西能使GC处理我这样的体系呢?另外文献里说的的trap和预柱一般贵么。。5000以上怕是老师不大同意了。。。

附上文献里说的预处理使用的东西:
1.For the samples, the whole of the 不挥发盐 was retained by aSample Textlocated between the injector and the chromatographic column. In this way, the result of the analysis was not affected by the presence of 盐, as we were able to verify experimentally.The trap was periodically cleaned to prevent the IL from coming into the column.
2.The amount of 盐 could not be analyzed via gas chromatography, because of the negligible vapor pressure of 盐; The 盐 was collected in a precolumn (cup linear), to avoid contamination of the analytical column.

谢谢呀谢谢!!

[ Last edited by 夏天的娃 on 2012-8-28 at 18:41 ]
回复此楼
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖

proxyz

金虫 (正式写手)

【答案】应助回帖

感谢参与,应助指数 +1
引用回帖:
13楼: Originally posted by 夏天的娃 at 2012-08-30 09:02:18
我们老师特别小心,老怕我的东西污染了柱子- -!。。因为含有不挥发物质。。可是中文都已经发了很多用GC处理类似体系的文献了,有用安捷伦的也有用国产的,而且也都没说在色谱上添加别的什么设备再防止污染。

我 ...

气化室就是衬管,这两个是一个东西
石英棉主要是防止固体的,对你的盐溶液阻隔能力有限
你这个直接打几针,柱子肯定挂

这个体系最容易的就是用顶空做,没有顶空的话你用溶剂萃取,分液以后进有机相就行了
15楼2012-08-30 09:19:49
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖

proxyz

金虫 (正式写手)

【答案】应助回帖

引用回帖:
18楼: Originally posted by 夏天的娃 at 2012-08-30 09:27:37
因为这个有机盐溶解性很强,不过也亲水。所以我又想用水把它从样品里萃取出来再打。

这个衬管的英文是trap么?我看到文献里是直接打然后说定期清理trap的~~


谢谢赐教!...

trap不是衬管,是类似于捕集肼一样的东西
你的有机盐沸点是多少?
19楼2012-08-30 09:59:39
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖

proxyz

金虫 (正式写手)

【答案】应助回帖

引用回帖:
17楼: Originally posted by 夏天的娃 at 2012-08-30 09:21:38
嗯。。液态的。

奇怪了。。难道大家做的东西都很干净么。。?
GC这么脆弱一点自卫能力都没得。。。...

GC做样都要前处理的,处理干净了才进样
20楼2012-08-30 09:59:59
已阅   回复此楼   关注TA 给TA发消息 送TA红花 TA的回帖
相关版块跳转 我要订阅楼主 夏天的娃 的主题更新
信息提示
请填处理意见