当前位置: 首页 > 晶体 >单晶有不少错误解析困难,请求帮助,谢谢!

单晶有不少错误解析困难,请求帮助,谢谢!

作者 jinshanli
来源: 小木虫 200 4 举报帖子
+关注

测出来的单晶有不少错误,说是单晶无序,请各位单晶解析高手帮忙解析一下,谢谢啦!
主要想确定结构中标红的两个基团相对构型,是顺式还是反式的,非常感谢!

 返回小木虫查看更多

今日热帖
  • 精华评论
  • 羊倌

    test-name_ALERT_alert-type_alert-level.
    Click on the hyperlinks for more details of the test.
    Alert level A
    EXPT005_ALERT_1_A  _exptl_crystal_description is missing
                Crystal habit description.
                The following tests will not be performed.
                CRYSR_01
    DIFF003_ALERT_1_A  _diffrn_measurement_device_type is missing
                Diffractometer make and type. Replaces _diffrn_measurement_type.
    PLAT183_ALERT_1_A Missing _cell_measurement_reflns_used Value ....     Please Do !  
    PLAT184_ALERT_1_A Missing _cell_measurement_theta_min Value ......     Please Do !  
    PLAT185_ALERT_1_A Missing _cell_measurement_theta_max Value ......     Please Do !  
    PLAT699_ALERT_1_A Missing _exptl_crystal_description Value .......     Please Do !  
    Alert level C
    PLAT041_ALERT_1_C Calc. and Reported SumFormula    Strings  Differ     Please Check
    PLAT043_ALERT_1_C Calculated and Reported Mol. Weight Differ by ..       2.02 Check
    PLAT052_ALERT_1_C Info on Absorption Correction Method   Not Given     Please Do !  
    PLAT053_ALERT_1_C Minimum Crystal Dimension Missing (or Error) ...     Please Check,

  • 羊倌

    test-name_ALERT_alert-type_alert-level.
    Click on the hyperlinks for more details of the test.
    Alert level A
    EXPT005_ALERT_1_A  _exptl_crystal_description is missing
                Crystal habit description.
                The following tests will not be performed.
                CRYSR_01
    DIFF003_ALERT_1_A  _diffrn_measurement_device_type is missing
                Diffractometer make and type. Replaces _diffrn_measurement_type.
    PLAT183_ALERT_1_A Missing _cell_measurement_reflns_used Value ....     Please Do !  
    PLAT184_ALERT_1_A Missing _cell_measurement_theta_min Value ......     Please Do !  
    PLAT185_ALERT_1_A Missing _cell_measurement_theta_max Value ......     Please Do !  
    PLAT699_ALERT_1_A Missing _exptl_crystal_description Value .......     Please Do !  
    Alert level C
    PLAT041_ALERT_1_C Calc. and Reported SumFormula    Strings  Differ     Please Check
    PLAT043_ALERT_1_C Calculated and Reported Mol. Weight Differ by ..       2.02 Check
    PLAT052_ALERT_1_C Info on Absorption Correction Method   Not Given     Please Do !  
    PLAT053_ALERT_1_C Minimum Crystal Dimension Missing (or Error) ...     Please Check

  • 我想更懂你29

    链接: https://pan.baidu.com/s/1Zb4qaDgj1s04-5GCbGqxLw 提取码: yw9j
    无序与否并不影响两个目标基团位置的判断

  • HDJ_Tokyo

    附件仅供参考。